Wind-driven natural ventilation for buildings with two openings on the same external wall

Abstract This study uses wind tunnel experiments to investigate the wind-driven ventilation for buildings with two openings on a single wall. The exchange rates are measured by the tracer gas decay method under different external wind speeds, directions and opening sizes. The experimental results indicate that the time-averaged pressure difference across the openings is much larger than the fluctuating pressure when the wind direction is θ  = 22.5–45°, and the ventilation rate can be predicted by the orifice equation. When the wind direction is θ  = 0° and 67.5–180°, the pressure difference across the openings is insignificant and the fluctuating pressure entrains air across the openings. The exchange rate is proportional to the root-mean-square of the pressure fluctuation. Furthermore, the dimensionless exchange rate of the shear-induced ventilation (wind is parallel to the openings) is found to be independent of the wind speed, opening area and location. The exchange rate for buildings with an internal partition is lower than that without a partition when the wind direction is θ  = 0–90°. A semi-empirical prediction model is proposed to calculate the exchange rate by incorporating the time-averaged pressure difference and pressure fluctuation. The application of the prediction model to compute the air change rate (ACH) is also discussed.

[1]  P. Linden THE FLUID MECHANICS OF NATURAL VENTILATION , 1999 .

[2]  Shinsuke Kato,et al.  Wind tunnel experiments on wind-induced natural ventilation rate in residential basements with areaway space , 2010 .

[3]  Per Heiselberg,et al.  Single-sided natural ventilation driven by wind pressure and temperature difference , 2008 .

[4]  Qingyan Chen,et al.  A new empirical model for predicting single-sided, wind-driven natural ventilation in buildings , 2012 .

[5]  Chia-Ren Chu,et al.  Wind-driven cross ventilation in long buildings , 2014 .

[6]  Chia-Ren Chu,et al.  The loss factors of building openings for wind-driven ventilation , 2010 .

[7]  Yu-Wen Wang,et al.  An experimental study of wind-driven cross ventilation in partitioned buildings , 2010 .

[8]  M. Sherman Tracer-gas techniques for measuring ventilation in a single zone , 1990 .

[9]  P. Heiselberg,et al.  The airborne transmission of infection between flats in high-rise residential buildings: Tracer gas simulation , 2007, Building and Environment.

[10]  Konstantinos-Stefanos Nikas,et al.  Experimental and numerical investigation of the tracer gas methodology in the case of a naturally cross-ventilated building , 2012 .

[11]  C. Chu,et al.  A laboratory experiment of shear-induced natural ventilation , 2011 .

[12]  H. Awbi Ventilation of buildings , 1873 .

[13]  M. Sandberg,et al.  Building Ventilation: Theory and Measurement , 1996 .

[14]  Yin-Hao Chiu,et al.  Turbulence effects on the discharge coefficient and mean flow rate of wind-driven cross-ventilation , 2009 .

[15]  Ryuichiro Yoshie,et al.  CFD modelling of unsteady cross ventilation flows using LES , 2008 .

[16]  Dries Berckmans,et al.  Influence of sampling positions on accuracy of tracer gas measurements in ventilated spaces. , 2009 .

[17]  Ryozo Ooka,et al.  A Wind Tunnel Experimental Analysis of the Ventilation Characteristics of a Room with Single-Sided Opening in Uniform Flow , 2006 .

[18]  Mats Sandberg,et al.  Evaluation of Discharge Coefficients for Window Openings in Wind Driven Natural Ventilation , 2006 .

[19]  Chia-Ren Chu,et al.  Wind-driven cross ventilation with internal obstacles , 2013 .

[20]  Andreas K. Athienitis,et al.  Airflow assessment in cross-ventilated buildings with operable façade elements , 2011 .

[21]  Liang Ji,et al.  WIND TUNNEL INVESTIGATION ON INFLUENCE OF FLUCTUATING WIND DIRECTION ON CROSS NATURAL VENTILATION , 2011 .