LED-based photoacoustic imaging for early detection of joint inflammation in rodents: towards achieving 3Rs in rheumatoid arthritis research

Synovial angiogenesis and hypoxia in the joints are biomarkers of Rheumatoid Arthritis (RA). The ability to probe blood and accurately estimate the oxygen concentration make multiwavelength Photoacoustic (PA) imaging a potential tool for early detection of RA. In this work, a multiwavelength LED-based PA imaging system was characterized based on its imaging depth, resolution and accuracy of oxygen saturation estimation. A multicenter 3R (Replace, Refine and Reduce) focused small animal study was conducted. The 3R strategy was devised by reusing RA animal models, in vivo imaging of healthy animals and ex vivo studies with human blood. RA animal cadaver models with different levels of synovial angiogenesis (control, positive RA and treated) were imaged and compared against results from a previous study using the same samples. An ex vivo PA oxygen saturation imaging using human blood was validated against oximeter readings and further verified it with in vivo animal studies. An imaging depth of 8 mm with an SNR of 10 dB was achieved for RA samples. A difference in PA intensity was observed for RA models compared to control and treated group. The PA oxygen saturation estimation correlates with oximeter readings, which is confirmed with in vivo studies. The results show the efficacy of the LED-based PA imaging system in RA diagnosis based on synovial angiogenesis and hypoxia. The imaging depth, resolution and oxygen saturation estimate are sufficient to differentiate RA samples from control. Our future work will focus on validating the method using arthritis animal models and demonstrating the 3R potential.

[1]  Wiendelt Steenbergen,et al.  Initial results of finger imaging using photoacoustic computed tomography , 2014, Journal of biomedical optics.

[2]  Xueding Wang,et al.  Characterization and treatment monitoring of inflammatory arthritis by photoacoustic imaging: a study on adjuvant-induced arthritis rat model , 2013, Biomedical optics express.

[3]  Srirang Manohar,et al.  Photoacoustic imaging in percutaneous radiofrequency ablation: device guidance and ablation visualization , 2019, Physics in medicine and biology.

[4]  Sumohana S. Channappayya,et al.  Characterization of lens based photoacoustic imaging system☆ , 2017, Photoacoustics.

[5]  J. Brian Fowlkes,et al.  Photoacoustic and ultrasound dual-modality imaging of human peripheral joints , 2013, Journal of biomedical optics.

[6]  W. Steenbergen,et al.  Recent Development of Technology and Application of Photoacoustic Molecular Imaging Toward Clinical Translation , 2018, The Journal of Nuclear Medicine.

[7]  Srirang Manohar,et al.  Current and future trends in photoacoustic breast imaging , 2019, Photoacoustics.

[8]  Wiendelt Steenbergen,et al.  Tomographic imaging with an LED-based photoacoustic-ultrasound system , 2020, BiOS.

[9]  Wiendelt Steenbergen,et al.  Feasibility of photoacoustic/ultrasound imaging of synovitis in finger joints using a point-of-care system , 2017, Photoacoustics.

[10]  Adrien E. Desjardins,et al.  Handheld Real-Time LED-Based Photoacoustic and Ultrasound Imaging System for Accurate Visualization of Clinical Metal Needles and Superficial Vasculature to Guide Minimally Invasive Procedures , 2018, Sensors.

[11]  Guan Xu,et al.  Detecting joint inflammation by an LED-based photoacoustic imaging system: a feasibility study , 2018, Journal of biomedical optics.

[12]  Yun Wu,et al.  Review on photoacoustic imaging of the brain using nanoprobes , 2016, Neurophotonics.

[13]  Makoto Yamakawa,et al.  Ring-array photoacoustic tomography for imaging human finger vasculature , 2019, Journal of biomedical optics.