Optimum Quadratic Filters for Nonlinear Ultrasonic Imaging

In this paper, we present a novel method of a quadratic filter (QF) design for separating nonlinearity in pulse–echo signals in order to improve the quality of ultrasound images. The design of QFs is performed in frequency domain. The two-dimensional (2D) frequency response of the optimum QF is composed of two 2D Gaussian functions with different spreads in their major and minor axes. The centers of the Gaussian functions are positioned at frequency pairs where the contrast-to-tissue (CTR) ratio is maximal along the main diagonal, i.e., major axis, of 2D frequency plane. The different spreads in major and minor axes offer two degrees of freedom in maximizing the CTR and axial resolution simultaneously. This avoids the inherent tradeoff between contrast and axial resolution when linear filters are used (e.g. in second harmonic imaging). We demonstrate the performance of the approach with echo data from two imaging targets, i.e., a flow phantom and a quality assurance phantom.

[1]  C. Chin,et al.  Pulse inversion Doppler: a new method for detecting nonlinear echoes from microbubble contrast agents , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  N de Jong,et al.  Ultrasound contrast imaging: current and new potential methods. , 2000, Ultrasound in medicine & biology.

[3]  Les E. Atlas,et al.  Quadratic detectors for energy estimation , 1995, IEEE Trans. Signal Process..

[4]  David Cosgrove,et al.  Ultrasound contrast agents: an overview. , 2006, European journal of radiology.

[5]  Sachiko Tanaka,et al.  Effectiveness of galactose-based intravenous contrast medium on color Doppler sonography of deeply located hepatocellular carcinoma. , 1995, Ultrasound in medicine & biology.

[6]  Weiping Zhu,et al.  A least-square design approach for 2D FIR filters with arbitrary frequency response , 1999 .

[7]  Charles T. Lancée,et al.  Higher harmonics of vibrating gas-filled microspheres. Part two: measurements , 1994 .

[8]  S. Kaul,et al.  Myocardial perfusion imaging in the setting of coronary artery stenosis and acute myocardial infarction using venous injection of a second-generation echocardiographic contrast agent. , 1997, Circulation.

[9]  E.S. Ebbini,et al.  Post-beamforming second-order Volterra filter for pulse-echo ultrasonic imaging , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  C. McArdle,et al.  Improved characterisation of focal liver tumours: dynamic power Doppler imaging using NC100100 echo-enhancer. , 2000, European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology.