A High-Efficiency 5-kW Soft-Switched Power Conditioning System for Low-Voltage Solid Oxide Fuel Cells

This paper presents a high-efficiency power conditioning system design that employs a soft-switched dc-dc converter and a soft-switched dc-ac inverter for a low-voltage 26-V, 5-kW solid oxide fuel cell. The dc-dc converter converts fuel cell voltage to a 400-V dc bus voltage using a 3-phase 6-leg phase-shift modulated converter to achieve higher than 96% peak efficiency with zero-voltage zero-current switching. The dc-ac inverter then produces 120/240V ac using a CoolMOS based soft-switching inverter to achieve 98% peak efficiency. The inverter output is universal for both standalone and grid-tie modes operation. The standalone load comes out of two sets of LC filter with a neutral line for equal voltage splits. For grid-tie mode, a circuit breaker needs to turn on, and an additional inductor is included for grid current ripple reduction. Test results indicated that peak efficiency of 94% is achieved for the two-stage power conversion PCS. In addition to high efficiency design, this paper also introduces advanced controls including fuel cell current ripple reduction using a current loop in the dc-dc converter and ac output current steady-state error reduction using an admittance compensation technique in the dc-ac inverter.

[1]  M. Liserre,et al.  Low-cost digital implementation of proportional-resonant current controllers for PV inverter applications using delta operator , 2005, 31st Annual Conference of IEEE Industrial Electronics Society, 2005. IECON 2005..

[2]  Donald Grahame Holmes,et al.  Stationary frame current regulation of PWM inverters with zero steady-state error , 2003 .

[3]  R. Gemmen Analysis for the Effect of Inverter Ripple Current on Fuel Cell Operating Condition , 2001, Heat Transfer: Volume 4 — Combustion and Energy Systems.

[4]  Jih-Sheng Lai,et al.  A synchronous rectification featured soft-switching inverter using CoolMOS , 2006, Twenty-First Annual IEEE Applied Power Electronics Conference and Exposition, 2006. APEC '06..

[5]  P.N. Enjeti,et al.  Development of an equivalent circuit model of a fuel cell to evaluate the effects of inverter ripple current , 2004, Nineteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2004. APEC '04..

[6]  Jih-Sheng Lai,et al.  Modeling and Control of a Novel Six-Leg Three-Phase High-Power Converter for Low Voltage Fuel Cell Applications , 2006, IEEE Transactions on Power Electronics.

[7]  Jih-Sheng Lai,et al.  Current Loop Control with Admittance Compensation for a Single-Phase Grid-Tie Fuel Cell Power Conditioning System , 2007, APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition.

[8]  J. Lai,et al.  Fuel cell and power conditioning system interactions , 2005, Twentieth Annual IEEE Applied Power Electronics Conference and Exposition, 2005. APEC 2005..

[9]  Donald Grahame Holmes,et al.  Stationary frame current regulation of PWM inverters with zero steady state error , 1999, 30th Annual IEEE Power Electronics Specialists Conference. Record. (Cat. No.99CH36321).

[10]  Jih-Sheng Lai,et al.  Source and Load Adaptive Design for a High-Power Soft-Switching Inverter , 2006, IEEE Transactions on Power Electronics.

[11]  Richard S. Zhang,et al.  A grid simulator with control of single-phase power converters in D-Q rotating frame , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[12]  T. Meynard,et al.  Interactions Between Fuel Cells and Power Converters: Influence of Current Harmonics on a Fuel Cell Stack , 2007, IEEE Transactions on Power Electronics.

[13]  Jih-Sheng Lai,et al.  A novel three-phase high-power soft-switched DC/DC converter for low-voltage fuel cell applications , 2005 .

[14]  Yukihiko Sato,et al.  A new control strategy for voltage type PWM rectifiers to realise zero steady-state control error in input current , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.