Comparison of two methodologies for calibrating satellite instruments in the visible and near infrared

Traditionally, satellite instruments that measure Earth-reflected solar radiation in the visible and near infrared wavelength regions have been calibrated for radiance response in a two-step method. In the first step, the spectral response of the instrument is determined using a nearly monochromatic light source, such as a lamp-illuminated monochromator. Such sources only provide a relative spectral response (RSR) for the instrument, since they do not act as calibrated sources of light nor do they typically fill the field-of-view of the instrument. In the second step, the instrument views a calibrated source of broadband light, such as a lamp-illuminated integrating sphere. In the traditional method, the RSR and the sphere spectral radiance are combined and, with the instrument's response, determine the absolute spectral radiance responsivity of the instrument. More recently, an absolute calibration system using widely tunable monochromatic laser systems has been developed. Using these sources, the absolute spectral responsivity (ASR) of an instrument can be determined on a wavelength-by-wavelength basis. From these monochromatic ASRs, the responses of the instrument bands to broadband radiance sources can be calculated directly, eliminating the need for calibrated broadband light sources such as integrating spheres. Here we describe the laser-based calibration and the traditional broad-band sourcebased calibration of the NPP VIIRS sensor, and compare the derived calibration coefficients for the instrument. Finally, we evaluate the impact of the new calibration approach on the on-orbit performance of the sensor.

[1]  Carl F. Schueler,et al.  NPOESS VIIRS sensor design overview , 2002, Optics + Photonics.

[2]  Eric Johnson,et al.  VIIRS initial performance verification. Subassembly, early integration and ambient phase I testing of EDU , 2005, Proceedings. 2005 IEEE International Geoscience and Remote Sensing Symposium, 2005. IGARSS '05..

[3]  Carl F. Schueler,et al.  VIIRS sensor performance , 2003, IGARSS 2003. 2003 IEEE International Geoscience and Remote Sensing Symposium. Proceedings (IEEE Cat. No.03CH37477).

[4]  G. Thuillier,et al.  The Solar Spectral Irradiance from 200 to 2400 nm as Measured by the SOLSPEC Spectrometer from the Atlas and Eureca Missions , 2003 .

[5]  H. Swenson,et al.  Using VIIRS to provide data continuity with MODIS , 2001, IGARSS 2001. Scanning the Present and Resolving the Future. Proceedings. IEEE 2001 International Geoscience and Remote Sensing Symposium (Cat. No.01CH37217).

[6]  George P Eppeldauer,et al.  Facility for spectral irradiance and radiance responsivity calibrations using uniform sources. , 2006, Applied optics.

[7]  James B. Young,et al.  Radiometric Measurement Comparison on the Integrating Sphere Source Used to Calibrate the Moderate Resolution Imaging Spectroradiometer (MODIS) and the Landsat 7 Enhanced Thematic Mapper Plus (ETM+) , 2003, Journal of research of the National Institute of Standards and Technology.

[8]  Robert A. Barnes,et al.  Modeling spectral effects in Earth-observing satellite instruments , 2007, SPIE Remote Sensing.