AC drive with permanent magnet synchronous motor and sensorless control

In the paper there are presented results of the sensorless control of AC drive with the permanent magnet synchronous motor. The method is based on the rotor magnetic flux components estimation. Practical realization was made by the microcomputer control system with the digital signal processor TMS320F2812. The graphical visualization of the electrical controlled drive was made by the software Lab View. The measured results of proposed laboratory stand with applied vector control and sensorless vector control were shown at the conclusion.

[1]  Peter Vas,et al.  Sensorless vector and direct torque control , 1998 .

[2]  J. Vittek,et al.  Forced dynamics control of electric drives employing pmsm with a flexible coupling , 2007, 2007 Australasian Universities Power Engineering Conference.

[3]  P ? ? ? ? ? ? ? % ? ? ? ? , 1991 .

[5]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[6]  P. Chlebis,et al.  Comparison of power losses and quality of output voltage from different types of inverters , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[7]  L. Osmancfk,et al.  Digital Signal Processor TMS320F2812 and Its Application in Electric Drives , 2006, 2006 International Conference on Applied Electronics.

[8]  Frede Blaabjerg,et al.  Comparative study of adaptive and inherently sensorless observers for variable-speed induction-motor drives , 2006, IEEE Transactions on Industrial Electronics.

[9]  Petr Chlebis,et al.  Method of Direct Torque Control for three-level Voltage Inverter , 2009, 2009 13th European Conference on Power Electronics and Applications.

[10]  Werner Leonhard,et al.  Control of Electrical Drives , 1990 .