A robust hysteresis current-controlled PWM inverter for linear PMSM driven magnetic suspended positioning system

Hysteresis current-controlled pulsewidth modulation (PWM) is very robust but it possesses nonconstant switching frequency, and it is difficult to use for high-performance position servo applications. This paper presents a robust hysteresis current-controlled PWM scheme for a magnetic suspended positioning system driven by an inverter-fed linear permanent-magnet synchronous motor having improved performance in these two areas. In the proposed control scheme, the conventional hysteresis PWM mechanism is augmented by a robust harmonic spectrum-shaping controller. The error signal, which represents the switching frequency deviated from the set one, is detected using a notching filter inverse model. Then, the current command is adjusted by a robust compensation signal. The hysteresis band can be equivalently varied to let the dominant harmonic frequency of inverter output be constant, wherein the frequency can easily be changed by tuning the center frequency of the notch filter. The gating signal of switches is not needed to be sensed for making the proposed control. The constant-frequency control performance yielded by the proposed controller is rather insensitive to the system disturbances and the neutral voltage variation due to isolated Y connection. Through applying the proposed PWM inverter, satisfactory position control requirements can be achieved by properly setting the dominant harmonic frequency according to the electromechanical model of the positioning system.

[1]  Paolo Tomasin,et al.  Improved constant-frequency hysteresis current control of VSI inverters with simple feed-forward bandwidth prediction , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.

[2]  S. J. Chiang,et al.  Robust control of multimodule current-mode controlled converters , 1993 .

[3]  Keith Glover,et al.  A loop-shaping design procedure using H/sub infinity / synthesis , 1992 .

[4]  B. Bose An adaptive hysteresis-band current control technique of a voltage-fed PWM inverter for machine drive system , 1990 .

[5]  Donald Grahame Holmes,et al.  A simple, novel method for variable-hysteresis-band current control of a three phase inverter with constant switching frequency , 1993, Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting.

[6]  Paresh C. Sen,et al.  Comparative analysis of fixed and sinusoidal band hysteresis current controllers for voltage source inverters , 1992, IEEE Trans. Ind. Electron..

[7]  J. Doyle,et al.  Robust and optimal control , 1995, Proceedings of 35th IEEE Conference on Decision and Control.

[8]  Paolo Tenti,et al.  A novel hysteresis control method for current-controlled voltage-source PWM inverters with constant modulation frequency , 1990 .

[9]  Hirofumi Akagi,et al.  A High Performance AC Servo System with Permanent Magnet Synchronous Motors , 1986, IEEE Transactions on Industrial Electronics.

[10]  Tae-Won Chun,et al.  Development of adaptive hysteresis band current control strategy of PWM inverter with constant switching frequency , 1996, Proceedings of Applied Power Electronics Conference. APEC '96.

[11]  Marian P. Kazmierkowski,et al.  Current control techniques for three-phase voltage-source PWM converters: a survey , 1998, IEEE Trans. Ind. Electron..

[12]  Joachim Holtz Pulsewidth modulation-a survey , 1992, IEEE Trans. Ind. Electron..

[13]  T. S. Radwan,et al.  Analysis of current controllers for voltage-source inverter , 1997, IEEE Trans. Ind. Electron..

[14]  Donald W. Novotny,et al.  Current Control of VSI-PWM Inverters , 1985, IEEE Transactions on Industry Applications.