On the estimation of characteristic indoor air quality parameters using analytical and numerical methods.

Indoor exposure to air contaminants penetrating from the outdoor environment depends on a number of key processes and parameters such as the ventilation rate, the geometric characteristics of the indoor environment, the outdoor concentration and the indoor removal mechanisms. In this study two alternative methods are used, an analytical and a numerical one, in order to study the time lag and the reduction of the variances of the indoor concentrations, and to estimate the deposition rate of the air contaminants in the indoor environment employing both indoor and outdoor measurements of air contaminants. The analytical method is based on a solution of the mass balance equation involving an outdoor concentration pulse which varies sinusoidally with the time, while the numerical method involves the application of the MIAQ indoor air quality model assuming a triangular pulse. The ratio of the fluctuation of the indoor concentrations to the outdoor ones and the time lag were estimated for different values of the deposition velocity, the ventilation rate and the duration of the outdoor pulse. Results have showed that the time lag between the indoor and outdoor concentrations is inversely proportional to the deposition and ventilation rates, while is proportional to the duration of the outdoor pulse. The decrease of the ventilation and the deposition rate results in a rapid decrement of the variance ratio of indoor to outdoor concentrations and to an increment of the variance ratio, respectively. The methods presented here can be applied for gaseous species as well as for particulate matter. The nomograms and theoretical relationships that resulted from the simulation results and the analytical methods respectively were used in order to study indoor air phenomena. In particular they were used for the estimation of SO2 deposition rate. Implications of the studied parameters to exposure studies were estimated by calculating the ratio of the indoor exposure to the exposure outdoors. Limitations of the methods were explored by testing various scenarios which are usually met in the indoor environment. Strong indoor emissions, intense chemistry and varying ventilation rates (opening and closing of the windows) were found to radically influence the time lag and fluctuation ratios.

[1]  H. Bloemen,et al.  Modeling Relationships between Indoor and Outdoor Air Quality , 2000, Journal of the Air & Waste Management Association.

[2]  Nancy J. Brown,et al.  A Concentration Rebound Method for Measuring Particle Penetration and Deposition in the Indoor Environment , 2002 .

[3]  Tracy L. Thatcher,et al.  Deposition, resuspension, and penetration of particles within a residence , 1995 .

[4]  Kenneth L. Heitner,et al.  Theoretical model for relating indoor pollutant concentrations to those outside , 1974 .

[5]  D Mark,et al.  Indoor / outdoor relationships of particulate matter in domestic homes with roadside, urban and rural locations , 2000 .

[6]  William W. Nazaroff,et al.  Concentration and Fate of Airborne Particles in Museums , 1990 .

[7]  Terje Grøntoft,et al.  Compilation of tables of surface deposition velocities for O3, NO2 and SO2 to a range of indoor surfaces , 2004 .

[8]  Thomas E McKone,et al.  Indoor particulate matter of outdoor origin: importance of size-dependent removal mechanisms. , 2002, Environmental science & technology.

[9]  William W. Nazaroff,et al.  Removal of reactive gases at indoor surfaces: Combining mass transport and surface kinetics , 1993 .

[10]  Relationships between indoor and outdoor contaminants in mechanically ventilated buildings , 1996 .

[11]  Zuohuan Zheng,et al.  Nonlinear coupling between thermal mass and natural ventilation in buildings , 2003 .

[12]  R. H. Sabersky,et al.  Concentrations, decay rates, and removal of ozone and their relation to establishing clean indoor air , 1973 .

[13]  N. Carslaw A new detailed chemical model for indoor air pollution , 2007 .

[14]  Francis Allard,et al.  Natural ventilation in buildings : a design handbook , 1998 .

[15]  M.N.A. Saïd Measurements of air change rates and air flow patterns in large single-cell buildings , 1997 .

[16]  Lidia Morawska,et al.  The relationship between indoor and outdoor airborne particles in the residential environment , 2001 .

[17]  Yifang Zhu,et al.  Penetration of freeway ultrafine particles into indoor environments , 2005 .

[18]  Andrew P. Jones,et al.  Indoor air quality and health , 1999 .

[19]  Ari Asmi,et al.  Indoor air measurement campaign in Helsinki, Finland 1999 – the effect of outdoor air pollution on indoor air , 2001 .

[20]  C. Weschler,et al.  Potential reactions among indoor pollutants , 1997 .

[21]  C. Zerefos,et al.  Measurements and numerical simulations of indoor O3 and NOx in two different cases , 1998 .

[22]  Christian Monn,et al.  Exposure assessment of air pollutants: a review on spatial heterogeneity and indoor/outdoor/personal exposure to suspended particulate matter, nitrogen dioxide and ozone , 2001 .

[23]  William W. Nazaroff,et al.  Mathematical Modeling of Indoor Aerosol Dynamics , 1989 .

[24]  P. Switzer,et al.  Derivation of an indoor air averaging time model from the mass balance equation for the case of independent source inputs and fixed air exchange rates , 1995 .

[25]  Kaarle Hämeri,et al.  Indoor and outdoor particle size characterization at a family house in Espoo-Finland , 2005 .

[26]  L. Morawska,et al.  Quantitative Assessment of the Effect of Surface Deposition and Coagulation on the Dynamics of Submicrometer Particles Indoors , 2003 .

[27]  Lidia Morawska,et al.  Particle deposition rates in residential houses , 2005 .

[28]  K. Lee,et al.  Characterization of indoor air quality using multiple measurements of nitrogen dioxide. , 2004, Indoor air.

[29]  Pavel Moravec,et al.  Indoor Aerosol Particle Deposition in an Empty Office , 2005 .