A surface-modified sperm sorting device with long-term stability

Microfluidic devices fabricated from poly (dime- thylsiloxane) (PDMS) offer the ability to improve our biological and medical capabilities. Although PDMS offers a range of intriguing benefits for biomedical applications, the intrinsically hydrophobic nature of PDMS may impede with the tremendous potential of these devices. Here, we describe a PDMS-based sperm sorting device, which has been surface-modified via graft-co-polymerization of poly(ethylene glycol) methyl ether methacrylate to create a moderately hydrophilic and non-fouling surface. This process involves the exposure of PDMS to UV/ozone, which activates the PDMS surface to bond to the substrate and, at the same time, initiates the graft-co-polymerization from the PDMS surface. In this study, we confirmed long-term stability of surface-modified PDMS for up to 56 days based on Fourier transformation infrared spectroscopy (FTIR), contact angle measurements, and protein adsorption studies. Moreover, the applicability of our method to PDMS-based sperm sorting devices was demonstrated by successfully sorting human sperm.

[1]  K. Neoh,et al.  Plasma-Induced Graft Polymerization of Poly(ethylene glycol) Methyl Ether Methacrylate on Si(100) Surfaces for Reduction in Protein Adsorption and Platelet Adhesion , 2002 .

[2]  K. Tan,et al.  Surface modification of stainless steel by grafting of poly(ethylene glycol) for reduction in protein adsorption. , 2001, Biomaterials.

[3]  Yu-Hwa Lo,et al.  UV/ozone modification of poly(dimethylsiloxane) microfluidic channels , 2004 .

[4]  Robert Langer,et al.  Reactive polymer coatings: a first step toward surface engineering of microfluidic devices. , 2003, Analytical chemistry.

[5]  Hai Bang Lee,et al.  Preparation and Characterization of Comb-like PEO Gradient Surfaces , 1996 .

[6]  Mark Bachman,et al.  Tailoring the surface properties of poly(dimethylsiloxane) microfluidic devices. , 2004, Langmuir : the ACS journal of surfaces and colloids.

[7]  Thomas Lippert,et al.  Photochemical Modification of Cross-Linked Poly(dimethylsiloxane) by Irradiation at 172 nm , 2004 .

[8]  S. Takayama,et al.  Rethinking gamete/embryo isolation and culture with microfluidics. , 2003, Human reproduction update.

[9]  G. Julius Vancso,et al.  Hydrophobic recovery of UV/ozone treated poly(dimethylsiloxane): adhesion studies by contact mechanics and mechanism of surface modification , 2005 .

[10]  G. Whitesides,et al.  Components for integrated poly(dimethylsiloxane) microfluidic systems , 2002, Electrophoresis.

[11]  J. Genzer,et al.  Surface modification of Sylgard-184 poly(dimethyl siloxane) networks by ultraviolet and ultraviolet/ozone treatment. , 2002, Journal of colloid and interface science.

[12]  Nancy Allbritton,et al.  Surface modification of poly(dimethylsiloxane) microfluidic devices by ultraviolet polymer grafting. , 2002, Analytical chemistry.

[13]  K. Neoh,et al.  Plasma-induced graft polymerization of poly(ethylene glycol) methyl ether methacrylate on poly(tetrafluoroethylene) films for reduction in protein adsorption , 2002 .

[14]  Detlev Belder,et al.  Surface modification in microchip electrophoresis , 2003, Electrophoresis.

[15]  G. Whitesides,et al.  Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies , 2003, Electrophoresis.

[16]  Shuichi Takayama,et al.  Passively driven integrated microfluidic system for separation of motile sperm. , 2003, Analytical chemistry.