Intraoperative evaluation of the spiral nerve cuff electrode on the femoral nerve trunk

Evaluation of the Case Western Reserve University spiral nerve cuff electrode on the femoral nerve trunk was performed intraoperatively in four subjects undergoing femoral-popliteal bypass surgery. The threshold, nerve size and selective activation capabilities of the electrode were examined. The activation thresholds for the first muscle to be recruited were 6.3, 9, 10.6, and 37.4 nC with pulse amplitudes ranging from 0.3 to 1 mA. The femoral nerve was found to have an elliptical cross-section with a major axis average length of 9 mm (8-12 mm) and a minor axis length of 1.5 mm. In all four subjects selective activation of the sartorius was obtained. In two subjects, the rectus femoris could also be selectively activated and in one subject the vastus medialis was selectively activated. Each electrode had four independent contacts that were evaluated separately. Small air bubbles were formed in the space over some contacts, preventing stimulation. This occurred in one contact in each electrode, leaving three effective stimulation channels. This issue has been corrected for future studies.

[1]  P H Peckham,et al.  Tissue response to chronically stimulated implanted epimysial and intramuscular electrodes. , 1997, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[2]  Ronald J Triolo,et al.  Fascicular anatomy of human femoral nerve: implications for neural prostheses using nerve cuff electrodes. , 2009, Journal of rehabilitation research and development.

[3]  D. Durand,et al.  Functionally selective peripheral nerve stimulation with a flat interface nerve electrode , 2002, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[4]  R J Triolo,et al.  Chronic stability and selectivity of four-contact spiral nerve-cuff electrodes in stimulating the human femoral nerve , 2009, Journal of neural engineering.

[5]  J. Stewart,et al.  Peripheral nerve fascicles: Anatomy and clinical relevance , 2003, Muscle & nerve.

[6]  M. Keith,et al.  Stimulation Stability and Selectivity of Chronically Implanted Multicontact Nerve Cuff Electrodes in the Human Upper Extremity , 2009, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[7]  Daniel K. Leventhal,et al.  Subfascicle Stimulation Selectivity with the Flat Interface Nerve Electrode , 2003, Annals of Biomedical Engineering.

[8]  R. Triolo,et al.  Performance of epimysial stimulating electrodes in the lower extremities of individuals with spinal cord injury , 2004, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[9]  J. Mortimer,et al.  A spiral nerve cuff electrode for peripheral nerve stimulation , 1988, IEEE Transactions on Biomedical Engineering.

[10]  M. Keith,et al.  Human Nerve Stimulation Thresholds and Selectivity Using a Multi-contact Nerve Cuff Electrode , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[11]  E. Delagi,et al.  Anatomic guide for the electromyographer--the limbs , 1980 .

[12]  J. Mortimer,et al.  Selective and independent activation of four motor fascicles using a four contact nerve-cuff electrode , 2004, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[13]  R. Triolo,et al.  A Model of Selective Activation of the Femoral Nerve With a Flat Interface Nerve Electrode for a Lower Extremity Neuroprosthesis , 2008, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[14]  W. Grill,et al.  Quantification of recruitment properties of multiple contact cuff electrodes. , 1996, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[15]  Michael W. Keith,et al.  A surgically-implanted intramuscular electrode for an implantable neuromuscular stimulation system , 1994 .