An improved resonant frequency based LCL filter design method for grid-connected inverters

Resonant frequency of an LCL filter in grid-connected inverters decreases with increase in inductive grid impedance. It is also affected by drop in magnetic permeability of filter inductor with increase in current. This resonant frequency variation affects grid-voltage harmonic rejection and compromises stability. Hence, an improved resonant frequency based LCL filter design method is presented in this paper. A resonant frequency band is identified by considering four factors: grid-voltage harmonics, grid strength, filter inductance non-linearity and control stability boundary. The LCL parameters are then derived so that the resonant frequency remains within this identified band for a wide operating range. Division-Summation digital control method is used to elaborate the design method. Experimental results have demonstrated stability and much improved harmonic rejection under wide parameter variations.

[1]  M. Liserre,et al.  Multiple harmonics control for three-phase grid converter systems with the use of PI-RES current controller in a rotating frame , 2006, IEEE Transactions on Power Electronics.

[2]  M. Liserre,et al.  Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values , 2006, IEEE Transactions on Power Electronics.

[3]  Johann W. Kolar,et al.  Optimal design of LCL harmonic filters for three-phase PFC rectifiers , 2011 .

[4]  M. Liserre,et al.  Design and control of an LCL-filter based three-phase active rectifier , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[5]  Marco Liserre,et al.  LCL-Filter Design for Robust Active Damping in Grid-Connected Converters , 2014, IEEE Transactions on Industrial Informatics.

[6]  Tsai-Fu Wu,et al.  Predictive Current Controlled 5-kW Single-Phase Bidirectional Inverter With Wide Inductance Variation for DC-Microgrid Applications , 2010, IEEE Transactions on Power Electronics.

[7]  Shaojun Xie,et al.  LCL-filter design for grid-connected inverter to suppress grid-induced low-order current harmonics , 2015, 2015 IEEE Energy Conversion Congress and Exposition (ECCE).

[8]  Jiu Dun Yan,et al.  Using virtual impedance to analyze the stability of LCL-filtered grid-connected inverters , 2015, 2015 IEEE International Conference on Industrial Technology (ICIT).

[9]  Tsai-Fu Wu,et al.  A D-$\Sigma$ Digital Control for Three-Phase Inverter to Achieve Active and Reactive Power Injection , 2014, IEEE Transactions on Industrial Electronics.

[10]  F. Blaabjerg,et al.  High Performance Current Controller for Selective Harmonic Compensation in Active Power Filters , 2007, IEEE Transactions on Power Electronics.

[11]  Josep M. Guerrero,et al.  Small-Signal Modeling of Digitally Controlled Grid-Connected Inverters With $LCL$ Filters , 2013, IEEE Transactions on Industrial Electronics.