Novel C-arm based cone-beam CT using a source trajectory of two concentric arcs

The first results from an interventional C-arm based computed tomography system where a complete source trajectory was used are presented. A scan with two arcs which are joined approximately at the center of their paths (CC trajectory) is utilized here. This trajectory satisfies Tuy's sufficiency condition for a large volume, but is not well populated with PI-lines. Therefore, a non-PI-line based reconstruction method is required. The desire for high dose efficiency led to the selection of an equal weighting based method. An FBP type reconstruction algorithm which was derived for two orthogonal concentric circles was utilized for reconstruction. The concept of a virtual image object was used to relate the projections from the two acquired non-orthogonal arcs to projections of a virtual object from two orthogonal arcs. Geometrical calibration is vital when performing tomography from an interventional system, and was incorporated here with the use of a homogeneous virtual projection matrix. The results demonstrate a significant reduction in cone-beam artifacts when the complete source trajectory is utilized.

[1]  D. Holdsworth,et al.  Use of a C-arm system to generate true three-dimensional computed rotational angiograms: preliminary in vitro and in vivo results. , 1997, AJNR. American journal of neuroradiology.

[2]  Biao Chen,et al.  Cone-beam volume CT breast imaging: feasibility study. , 2002, Medical physics.

[3]  J. Boone,et al.  Dedicated breast CT: radiation dose and image quality evaluation. , 2001, Radiology.

[4]  S. Leng,et al.  A shift-invariant filtered backprojection (FBP) cone-beam reconstruction algorithm for the source trajectory of two concentric circles using an equal weighting scheme. , 2006, Physics in medicine and biology.

[5]  Rolf Clackdoyle,et al.  Cone-beam reconstruction using the backprojection of locally filtered projections , 2005, IEEE Transactions on Medical Imaging.

[6]  Xiaochuan Pan,et al.  Theory and algorithms for image reconstruction on chords and within regions of interest. , 2005, Journal of the Optical Society of America. A, Optics, image science, and vision.

[7]  Hiroyuki Kudo,et al.  General reconstruction theory for multislice X-ray computed tomography with a gantry tilt , 2004, IEEE Transactions on Medical Imaging.

[8]  H. Tuy AN INVERSION FORMULA FOR CONE-BEAM RECONSTRUCTION* , 1983 .

[9]  Y. Trousset,et al.  Geometrical calibration of X-ray imaging chains for three-dimensional reconstruction. , 1993, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[10]  J H Siewerdsen,et al.  Cone-beam computed tomography with a flat-panel imager: initial performance characterization. , 2000, Medical physics.

[11]  D. Parker Optimal short scan convolution reconstruction for fan beam CT , 1982 .

[12]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[13]  B. Wilson,et al.  Volume CT with a flat-panel detector on a mobile, isocentric C-arm: pre-clinical investigation in guidance of minimally invasive surgery. , 2005, Medical physics.

[14]  Cyril Riddell,et al.  Design and development of C-arm based cone-beam CT for image-guided interventions: initial results , 2006, SPIE Medical Imaging.

[15]  A. Katsevich A GENERAL SCHEME FOR CONSTRUCTING INVERSION ALGORITHMS FOR CONE BEAM CT , 2003 .

[16]  J H Stanley,et al.  Dose minimization in computed tomography overscanning. , 1981, Medical physics.

[17]  Guang-Hong Chen An alternative derivation of Katsevich's cone-beam reconstruction formula. , 2003, Medical physics.

[18]  K F King,et al.  Computed tomography scanning with simultaneous patient translation. , 1990, Medical physics.

[19]  A. Katsevich Image reconstruction for the circle-and-arc trajectory , 2004, Physics in medicine and biology.

[20]  Nassir Navab,et al.  Enhanced 3D-reconstruction algorithms for C-Arm based interventional procedures , 2000, IEEE Trans. Medical Imaging.