Evaluation of a sonographic PACS in clinical practice: analysis of technical and analytical time savings.

The aim of this study was to generate quantitative data regarding technical and analytical time savings obtained by use of an ultrasonographic PACS. Data/time cards were recorded for each patient encountered in an outpatient diagnostic ultrasound facility for a 4 week period immediately before and a 1 year period after installation of a PACS environment. Use of a sonographic PACS resulted in a per case time savings of 293 s in the technical component and 51 to 63 s in the analytical component of an average ultrasonographic examination. We conclude that use of a PACS workstation has the potential to increase productivity for both the sonographer and the radiologist.

[1]  K S Berbaum,et al.  Evaluation of a PACS workstation for assessment of body CT studies. , 1990, Journal of computer assisted tomography.

[2]  H. K. Huang,et al.  Infrastructure design of a picture archiving and communication system. , 1992, AJR. American journal of roentgenology.

[3]  R H Choplin,et al.  Evaluation of PACS in ultrasonography , 1992, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[4]  R K Taira,et al.  Implementation of a large-scale picture archiving and communication system. , 1993, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[5]  H K Huang Three methods of implementing a picture archiving and communication system. , 1992, Radiographics : a review publication of the Radiological Society of North America, Inc.