Test target for characterizing 3D resolution of optical coherence tomography

Optical coherence tomography (OCT) is a non-invasive 3D imaging technology which has been applied or investigated in many diagnostic fields including ophthalmology, dermatology, dentistry, cardiovasology, endoscopy, brain imaging and so on. Optical resolution is an important characteristic that can describe the quality and utility of an image acquiring system. We employ 3D printing technology to design and fabricate a test target for characterizing 3D resolution of optical coherence tomography. The test target which mimics USAF 1951 test chart was produced with photopolymer. By measuring the 3D test target, axial resolution as well as lateral resolution of a spectral domain OCT system was evaluated. For comparison, conventional microscope and surface profiler were employed to characterize the 3D test targets. The results demonstrate that the 3D resolution test targets have the potential of qualitatively and quantitatively validating the performance of OCT systems.

[1]  S. A. Hojjatoleslami,et al.  Two applications of solid phantoms in performance assessment of optical coherence tomography systems. , 2013, Applied optics.

[2]  Ruo Yu Gu,et al.  Variable-sized bar targets for characterizing three-dimensional resolution in OCT , 2012, Biomedical optics express.

[3]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.

[4]  Jeeseong Hwang,et al.  Fabrication and characterization of a multilayered optical tissue model with embedded scattering microspheres in polymeric materials , 2012, Biomedical optics express.

[5]  D. D. de Bruin,et al.  Optical phantoms of varying geometry based on thin building blocks with controlled optical properties. , 2010, Journal of biomedical optics.

[6]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991, LEOS '92 Conference Proceedings.

[7]  Brendan F Kennedy,et al.  Structured three-dimensional optical phantom for optical coherence tomography. , 2011, Optics express.

[8]  Joshua Pfefer,et al.  System-independent assessment of OCT axial resolution with a "bar chart" phantom , 2011, BiOS.

[9]  Rebekah Drezek,et al.  Three-dimensional characterization of optical coherence tomography point spread functions with a nanoparticle-embedded phantom. , 2010, Optics letters.

[10]  Peter H. Tomlins,et al.  Point-spread function phantoms for optical coherence tomography. , 2009 .

[11]  Kelsey M. Kennedy,et al.  Review of tissue simulating phantoms with controllable optical, mechanical and structural properties for use in optical coherence tomography , 2012, Biomedical optics express.

[12]  J. Fujimoto Optical coherence tomography for ultrahigh resolution in vivo imaging , 2003, Nature Biotechnology.