An efficient technique based on DORT method to locate multiple soft faults in wiring networks

Decomposition of the time reversal operator (DORT) recently adopted to wiring fault detection and localization presented effectual results when dealing with a single soft fault along with complex network configurations. On the other hand, it failed in handling the task of locating multiple faults within even simple ones. In this paper, we propose an enhanced version of the standard DORT technique (EDORT) which is based on a complementary procedure enabling the accurate and selective localization of multiple soft faults in various wiring systems.

[1]  Lionel Pichon,et al.  A Noniterative Method for Locating Soft Faults in Complex Wire Networks , 2013, IEEE Transactions on Vehicular Technology.

[2]  P. Drummond,et al.  Time reversed acoustics , 1997 .

[3]  Cynthia Furse,et al.  A critical comparison of reflectometry methods for location of wiring faults , 2006 .

[4]  Cynthia Furse,et al.  An inexpensive distance measuring system for navigation of robotic vehicles , 2002 .

[5]  You Chung Chung,et al.  Application of phase detection frequency domain reflectometry for locating faults in an F-18 flight control harness , 2005, IEEE Transactions on Electromagnetic Compatibility.

[6]  Fabrice Auzanneau,et al.  WIRE TROUBLESHOOTING AND DIAGNOSIS: REVIEW AND PERSPECTIVES , 2013 .

[7]  M. Fink,et al.  Time reversal of ultrasonic fields. I. Basic principles , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  M. Fink,et al.  Self focusing in inhomogeneous media with time reversal acoustic mirrors , 1989, Proceedings., IEEE Ultrasonics Symposium,.

[9]  Paul Smith,et al.  Spread spectrum sensors for critical fault location on live wire networks , 2005 .

[10]  C. Furse An inexpensive distance measuring system for location of robotic vehicles , 1999, IEEE Antennas and Propagation Society International Symposium. 1999 Digest. Held in conjunction with: USNC/URSI National Radio Science Meeting (Cat. No.99CH37010).

[11]  Mathias Fink,et al.  Eigenmodes of the time reversal operator: a solution to selective focusing in multiple-target media , 1994 .

[12]  Antje Sommer,et al.  Electromagnetic Compatibility Engineering , 2016 .

[13]  Lionel Pichon,et al.  An efficient technique based on DORT method to locate multiple soft faults in wiring networks , 2015 .

[14]  Mathias Fink,et al.  Decomposition of the time reversal operator: Detection and selective focusing on two scatterers , 1996 .

[15]  Cynthia Furse,et al.  Down to the wire [aircraft wiring] , 2001 .

[16]  T. Sarkar,et al.  Analysis of Multiconductor Transmission Lines , 1988, 31st ARFTG Conference Digest.

[17]  G. Kalbarczyk Down to the wire , 2012, BDJ.

[18]  Lionel Pichon,et al.  Locating Multiple Soft Faults in Wire Networks Using an Alternative DORT Implementation , 2016, IEEE Transactions on Instrumentation and Measurement.