A simple droplet merger design for controlled reaction volumes

Droplet microfluidics has been proven to be a viable platform for a variety of reactions by using uniform droplets well encapsulated by an immiscible carrier medium as reaction vesicles. Merging as one of the most basic forms of droplet manipulation is highly demanded in controlling the concentration of reagents for reactions. After preliminary testing of several reported passive merging designs, it is found that most of them are prone to fabrication and operation uncertainties which limit their application for practical use. In this work, we present a simple design for merging variable numbers of droplets with a valve-type function which enables a critical volume limit to be imposed to the final product droplet. When the product droplet reaches the critical volume limit, it will block the exit of the merging chamber serving as the close mode of the valve. As a result, the pressure upstream is built up which forces the product droplet to exit the merger. The relationship between the numbers of droplets merged, the length of input droplets and the length of output droplets is used to tune the design parameters such as the chamber length, pillar array dimensions and bypass channel dimensions according to the desired set of reactions. The simplicity of the design allows for easier design and configuration to a desired purpose and lows down the risk of failures due to fabrication and operation uncertainties. The single-input–single-output design minimizes pressure disturbances from propagating downstream and reduces the complexity of integration into a larger LOC system. The geometry can be scaled up with little to no observable effect on the mode of operation.

[1]  Gi-Ra Yi,et al.  Synchronized reinjection and coalescence of droplets in microfluidics. , 2012, Lab on a chip.

[2]  Nam-Trung Nguyen,et al.  Thermocoalescence of microdroplets in a microfluidic chamber , 2012 .

[3]  Hongkai Wu,et al.  Recent Developments in Microfluidics for Cell Studies , 2014, Advanced materials.

[4]  J. Yoo,et al.  Droplet merging in a straight microchannel using droplet size or viscosity difference , 2010 .

[5]  Experimental study of microbubble coalescence in a T-junction microfluidic device , 2012 .

[6]  Chris R Kleijn,et al.  Predictive model for the size of bubbles and droplets created in microfluidic T-junctions. , 2010, Lab on a chip.

[7]  David S. W. Lim,et al.  Simultaneous generation of multiple aqueous droplets in a microfluidic device. , 2008, Analytica chimica acta.

[8]  Pelin Kubra Isgor,et al.  Microfluidic droplet content detection using integrated capacitive sensors , 2015 .

[9]  A. Lee,et al.  Alternating droplet generation and controlled dynamic droplet fusion in microfluidic device for CdS nanoparticle synthesis. , 2006, Lab on a chip.

[10]  Andrew D Griffiths,et al.  Droplet-based microreactors for the synthesis of magnetic iron oxide nanoparticles. , 2008, Angewandte Chemie.

[11]  A. Griffiths,et al.  High-resolution dose–response screening using droplet-based microfluidics , 2011, Proceedings of the National Academy of Sciences of the United States of America.

[12]  S. Anna,et al.  Coalescence and splitting of confined droplets at microfluidic junctions. , 2009, Lab on a chip.

[13]  D. Weitz,et al.  Geometrically mediated breakup of drops in microfluidic devices. , 2003, Physical review letters.

[14]  Tomasz Glawdel,et al.  Droplet formation in microfluidic T-junction generators operating in the transitional regime. I. Experimental observations. , 2012, Physical review. E, Statistical, nonlinear, and soft matter physics.

[15]  A. Abate,et al.  High-throughput injection with microfluidics using picoinjectors , 2010, Proceedings of the National Academy of Sciences.

[16]  Andrew D Griffiths,et al.  A fast and efficient microfluidic system for highly selective one-to-one droplet fusion. , 2009, Lab on a chip.

[17]  Karan V. I. S. Kaler,et al.  Droplet Microfluidics for Chip-Based Diagnostics , 2014, Sensors.

[18]  Tomasz Glawdel,et al.  Droplet formation in microfluidic T-junction generators operating in the transitional regime. II. Modeling. , 2012, Physical review. E, Statistical, nonlinear, and soft matter physics.

[19]  Z. G. Li,et al.  Fast on-demand droplet fusion using transient cavitation bubbles. , 2011, Lab on a chip.

[20]  D. Weitz,et al.  Droplet microfluidics for high-throughput biological assays. , 2012, Lab on a chip.

[21]  Varun Trivedi,et al.  A modular approach for the generation, storage, mixing, and detection of droplet libraries for high throughput screening. , 2010, Lab on a chip.

[22]  Janusz Pawliszyn,et al.  Side-by-side comparison of disposable microchips with commercial capillary cartridges for application in capillary isoelectric focusing with whole column imaging detection. , 2008, Lab on a chip.

[23]  Kan Liu,et al.  Droplet-based synthetic method using microflow focusing and droplet fusion , 2007 .

[24]  Tomasz Glawdel,et al.  Droplet formation in microfluidic T-junction generators operating in the transitional regime. III. Dynamic surfactant effects. , 2012, Physical review. E, Statistical, nonlinear, and soft matter physics.

[25]  Shuichi Shoji,et al.  Active microdroplet merging by hydrodynamic flow control using a pneumatic actuator-assisted pillar structure. , 2014, Lab on a chip.

[26]  Vittorio Cristini,et al.  Design of microfluidic channel geometries for the control of droplet volume, chemical concentration, and sorting. , 2004, Lab on a chip.

[27]  Yu-Chuan Su,et al.  On-demand liquid-in-liquid droplet metering and fusion utilizing pneumatically actuated membrane valves , 2008 .

[28]  G. Whitesides,et al.  Formation of droplets and bubbles in a microfluidic T-junction-scaling and mechanism of break-up. , 2006, Lab on a chip.

[29]  Tomasz Glawdel,et al.  Passive droplet trafficking at microfluidic junctions under geometric and flow asymmetries. , 2011, Lab on a chip.

[30]  A. deMello,et al.  Pillar-induced droplet merging in microfluidic circuits. , 2008, Lab on a chip.

[31]  Amar S Basu,et al.  Droplet morphometry and velocimetry (DMV): a video processing software for time-resolved, label-free tracking of droplet parameters. , 2013, Lab on a chip.

[32]  F. Mugele,et al.  Droplets Formation and Merging in Two-Phase Flow Microfluidics , 2011, International journal of molecular sciences.

[33]  D. Chiu,et al.  Selective encapsulation of single cells and subcellular organelles into picoliter- and femtoliter-volume droplets. , 2005, Analytical chemistry.

[34]  M. S. Boybay,et al.  Microwave sensing and heating of individual droplets in microfluidic devices. , 2013, Lab on a chip.

[35]  Aaron R Wheeler,et al.  Microfluidic device for single-cell analysis. , 2003, Analytical chemistry.

[36]  F. White Viscous Fluid Flow , 1974 .

[37]  Hun Lee,et al.  Fusion and sorting of two parallel trains of droplets using a railroad-like channel network and guiding tracks. , 2012, Lab on a chip.

[38]  Jihye Kim,et al.  Growth kinetics of microalgae in microfluidic static droplet arrays , 2012, Biotechnology and bioengineering.

[39]  A. Lee,et al.  Droplet coalescence by geometrically mediated flow in microfluidic channels , 2007 .

[40]  Stephan Herminghaus,et al.  Optimized droplet-based microfluidics scheme for sol-gel reactions. , 2010, Lab on a chip.

[41]  Helen Song,et al.  A microfluidic system for controlling reaction networks in time. , 2003, Angewandte Chemie.

[42]  Patrick Tabeling,et al.  Recent progress in the physics of microfluidics and related biotechnological applications. , 2014, Current opinion in biotechnology.

[43]  Nicolas Bremond,et al.  Decompressing emulsion droplets favors coalescence. , 2008, Physical review letters.