Validity and reliability of pressure-measurement insoles for vertical ground reaction force assessment in field situations.

This study aimed to test the validity and reliability of pressure-measurement insoles (medilogic® insoles) when measuring vertical ground reaction forces in field situations. Various weights were applied to and removed from the insoles in static mechanical tests. The force values measured simultaneously by the insoles and force plates were compared for 15 subjects simulating work activities. Reliability testing during the static mechanical tests yielded an average interclass correlation coefficient of 0.998. Static loads led to a creeping pattern of the output force signal. An individual load response could be observed for each insole. The average root mean square error between the insoles and force plates ranged from 6.6% to 17.7% in standing, walking, lifting and catching trials and was 142.3% in kneeling trials. The results show that the use of insoles may be an acceptable method for measuring vertical ground reaction forces in field studies, except for kneeling positions.

[1]  Annalee Yassi,et al.  Work-relatedness of low back pain in nursing personnel: a systematic review , 2013, International journal of occupational and environmental health.

[2]  F C T van der Helm,et al.  Inverse dynamics calculations during gait with restricted ground reaction force information from pressure insoles. , 2006, Gait & posture.

[3]  Hongwei Hsiao,et al.  Accuracy and precision of two in-shoe pressure measurement systems , 2002, Ergonomics.

[4]  S. Solomonidis,et al.  Evaluation of the gait analysis FSCAN pressure system: clinical tool or toy? , 2000 .

[5]  Rezaul K. Begg,et al.  Foot Plantar Pressure Measurement System: A Review , 2012, Sensors.

[6]  A Arndt,et al.  Correction for sensor creep in the evaluation of long-term plantar pressure data. , 2003, Journal of biomechanics.

[7]  J. Woodburn,et al.  Observations on the F-Scan in-shoe pressure measuring system. , 1996, Clinical biomechanics.

[8]  S Ino,et al.  An in-shoe device to measure plantar pressure during daily human activity. , 2011, Medical engineering & physics.

[9]  Paul R. Fleming,et al.  Evaluation of pressure insoles during running , 2010 .

[10]  A. Faivre,et al.  Instrumented shoes for pathological gait assessment , 2004 .

[11]  M. Koch,et al.  Plantardruckmessung im Konfektionsschuh mit der TEKSCAN Sensorfolie. In-shoe Plantar Measurement with TEKSCAN Sensor System , 1993 .

[12]  Sigmund A. Anderssen,et al.  Comparison of self-reported versus accelerometer-measured physical activity. , 2014, Medicine and science in sports and exercise.

[13]  F C T van der Helm,et al.  Use of pressure insoles to calculate the complete ground reaction forces. , 2004, Journal of biomechanics.

[14]  L. Klepper Use of a method for calculation of equivalent radiation conditions for increasing the amount of useful clinical information and calculating the dependence of lesion focus resorption probability on lesion volume and total dose absorbed by the lesion focus , 2004 .

[15]  P. Veltink,et al.  Evaluation of instrumented shoes for ambulatory assessment of ground reaction forces. , 2007, Gait & posture.

[16]  Kalev Kuklane,et al.  A field study in dairy farms: thermal condition of feet , 1999 .

[17]  J Winkel,et al.  Guidelines for occupational musculoskeletal load as a basis for intervention: a critical review. , 1996, Applied ergonomics.

[18]  Rachel M. Barkley,et al.  Physiological Versus Perceived Foot Temperature, and Perceived Comfort, during Treadmill Running in Shoes and Socks of Various Constructions , 2011 .

[19]  S J Dixon,et al.  Footscan pressure insoles: accuracy and reliability of force and pressure measurements in running. , 2010, Gait & posture.

[20]  M Koch [Measuring plantar pressure in conventional shoes with the TEKSCAN sensory system]. , 1993, Biomedizinische Technik. Biomedical engineering.

[21]  Kai-Ming Chan,et al.  Estimating the complete ground reaction forces with pressure insoles in walking. , 2008, Journal of biomechanics.

[22]  Edward D. Lemaire,et al.  Temperature and measurement changes over time for F-Scan sensors , 2013, 2013 IEEE International Symposium on Medical Measurements and Applications (MeMeA).

[23]  H J Stam,et al.  Accuracy and repeatability of the Pedar Mobile system in long-term vertical force measurements. , 2006, Gait & posture.

[24]  Pascal Madeleine,et al.  Are forward bending of the trunk and low back pain associated among Danish blue-collar workers? A cross-sectional field study based on objective measures , 2015, Ergonomics.

[25]  A J van der Beek,et al.  Assessment of mechanical exposure in ergonomic epidemiology. , 1998, Occupational and environmental medicine.