Water management of the DMFC passively fed with a high-concentration methanol solution

Abstract The methanol barrier layer adopted for high-concentration direct methanol fuel cells (HC-DMFCs) increases water transport resistance, and makes water management in HC-DMFCs more challenging and critical than that in the conventional direct methanol fuel cell (DMFC) without a methanol barrier layer. In the semi-passive HC-DMFC used in this work, oxygen was actively supplied to the cathode side while various concentrated methanol solutions, 4 M, 8 M, 16 M, and neat methanol, were passively supplied from the anode fuel reservoir. The effects of the cathode relative humidity, cathode pressure, and oxygen flow rate on the water crossover coefficient, fuel efficiency, and overall performance of the fuel cell were studied. Results showed that electrolyte membrane resistance, which was determined by its water content, was the predominant factor that determined the performance of a HC-DMFC, especially at a high current density. A negative water crossover coefficient, which indicated that water flowed back from the cathode through the electrolyte membrane to the anode, was measured when the methanol concentration was 8 M or higher. The back flow of water from the cathode is a very important water supply source to hydrate the electrolyte membrane. The water crossover coefficient was decreased by increasing the cathode relative humidity and back pressure. Water flooding at the cathode was not severe in the HC-DMFC, and a low oxygen flow rate was preferred to decrease water loss and yield a better performance. The peak power density generated from the HC-DMFC fed with 16 M methanol solution was 75.9 mW cm −2 at 70 °C.

[1]  Shimshon Gottesfeld,et al.  Electro‐osmotic Drag of Water in Ionomeric Membranes New Measurements Employing a Direct Methanol Fuel Cell , 1997 .

[2]  Mohammad Ali Abdelkareem,et al.  Effect of oxygen and methanol supply modes on the performance of a DMFC employing a porous plate , 2007 .

[3]  C. Agert,et al.  Passively operated vapor-fed direct methanol fuel cells for portable applications , 2008 .

[4]  Hideki Kuroki,et al.  DMFC performances using a pore-filling polymer electrolyte membrane for portable usages , 2005 .

[5]  Tianshou Zhao,et al.  In situ measurements of water crossover through the membrane for direct methanol fuel cells , 2007 .

[6]  Ya-Ling He,et al.  Exergy flow and energy utilization of direct methanol fuel cells based on a mathematic model , 2008 .

[7]  Rong Chen,et al.  Small direct methanol fuel cells with passive supply of reactants , 2009 .

[8]  A. Faghri,et al.  Challenges and opportunities of thermal management issues related to fuel cell technology and modeling , 2005 .

[9]  P. Ekdunge,et al.  Proton Conductivity of Nafion 117 as Measured by a Four‐Electrode AC Impedance Method , 1996 .

[10]  J. Nam,et al.  Optimum ionic conductivity and diffusion coefficient of ion-exchange membranes at high methanol feed concentrations in a direct methanol fuel cell , 2006 .

[11]  I-Ming Hsing,et al.  Flexible graphite-based integrated anode plate for direct methanol fuel cells at high methanol feed concentration , 2007 .

[12]  Mohammad Ali Abdelkareem,et al.  DMFC employing a porous plate for an efficient operation at high methanol concentrations , 2006 .

[13]  Amir Faghri,et al.  Water and air management systems for a passive direct methanol fuel cell , 2007 .

[14]  Fuqiang Liu,et al.  Water Transport Through Nafion 112 Membrane in DMFCs , 2005 .

[15]  Tianshou Zhao,et al.  Modeling of water transport through the membrane electrode assembly for direct methanol fuel cells , 2008 .

[16]  Tianshou Zhao,et al.  Microscopic characterizations of membrane electrode assemblies prepared under different hot-pressing conditions , 2007 .

[17]  A. Faghri,et al.  Transport phenomena in a semi-passive direct methanol fuel cell , 2010 .

[18]  Y. Pan,et al.  Direct Methanol Fuel Cell with Concentrated Solutions , 2006 .

[19]  Rong Chen,et al.  Mass transport phenomena in direct methanol fuel cells , 2009 .