Optimal Automatic Generation Control of Interconnected Power System Considering New Structures of Matrix Q

Abstract This article presents optimal automatic generation control regulator designs considering different methods of designing state cost-weighting matrix “Q.” The various aspects of observability and controllability of the system states, which influence the system dynamics directly or indirectly, are incorporated in the design of optimal automatic generation control regulators. For the investigation, a two-area interconnected power system with identical plants consisting of non-reheat turbines is considered. An AC transmission line in parallel a with DC transmission link is taken as area interconnection. The full state feedback control strategy has been applied to get optimal gains of the automatic generation control regulators. The pattern of closed-loop system eigenvalues, optimal gains, and system dynamic response plots in the wake of load disturbance are achieved with the implementation of the different optimal automatic generation control regulators to analyze the system stability and its dynamic performance.

[1]  J. Nanda,et al.  Transactions on Power Apparatus and Systems , Vol . PAS-1 O 0 , No . 5 , May 1981 SAMPLED-DATA AUTOMATIC GENERATION CONTROL OF INTERCONNECTED REHEAT THERMAL SYSTEMS CONSIDERING GENERATION RATE CONSTRAINTS , 2006 .

[2]  Paul C. Krause,et al.  Damping of Power Swings in a Parallel AC and DC System , 1966 .

[3]  K. R. Padiyar Hvdc Power Transmission Systems: Technology and System Interactions , 1991 .

[4]  A. Kanchanaharuthai Optimal sampled-data controller design with time-multiplied performance index for load-frequency control , 2004, Proceedings of the 2004 IEEE International Conference on Control Applications, 2004..

[5]  Ibraheem,et al.  AGC strategies : A comprehensive review , 1996 .

[6]  S. P. Ghoshal,et al.  Application of GA/GA-SA based fuzzy automatic generation control of a multi-area thermal generating system , 2004 .

[7]  Prabhat Kumar,et al.  DYNAMIC PERFORMANCE EVALUATION OF 2-AREA INTERCONNECTED POWER SYSTEMS : A COMPARATIVE STUDY , 1998 .

[8]  B. L. Kaul,et al.  Automatic generation control of an interconnected power system , 1978 .

[9]  Nathan Cohn,et al.  Techniques for Improving the Control of Bulk Power Transfers on Interconnected Systems , 1971 .

[10]  C. Concordia,et al.  Tie-Line Power and Frequency Control of Electric Power Systems - Part II [includes discussion] , 2008, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[11]  Victor M. Becerra,et al.  Optimal control , 2008, Scholarpedia.

[12]  Samuel Ndubisi,et al.  An intelligent fuzzy logic controller applied to multi-area load frequency control , 2010 .

[13]  B. Anderson,et al.  Optimal control: linear quadratic methods , 1990 .

[14]  R. Kálmán On the general theory of control systems , 1959 .

[15]  Nathan Cohn,et al.  Methods of controlling generation on interconnected power systems , 1961, Electrical Engineering.

[16]  Tain-Sou Tsay Load–frequency control of interconnected power system with governor backlash nonlinearities , 2011 .

[17]  Baik Kim,et al.  Fuzzy logic based extended integral control for load frequency control , 2001, 2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194).

[18]  Chia-Feng Juang,et al.  Power system load frequency control by genetic fuzzy gain scheduling controller , 2005 .

[19]  Deqiang Gan,et al.  Optimal Automatic Generation Control (AGC) Dispatching and Its Control Performance Analysis for the Distribution Systems with DGs , 2007, 2007 IEEE Power Engineering Society General Meeting.

[20]  J. Nanda,et al.  AUTOMATIC GENERATION CONTROL OF A HYDROTHERMAL SYSTEM WITH NEW AREA CONTROL ERROR CONSIDERING GENERATION RATE CONSTRAINT , 1990 .

[21]  B. Moore Principal component analysis in linear systems: Controllability, observability, and model reduction , 1981 .

[22]  Nathan Cohn,et al.  Some Aspects of Tie-Line Bias Control on Interconnected Power Systems [includes discussion] , 1956, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[23]  A. Feliachi,et al.  Decentralized load frequency control for load following services , 2002, 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309).

[24]  J. Nanda,et al.  Some new findings on automatic generation control of an interconnected hydrothermal system with conventional controllers , 2006, IEEE Transactions on Energy Conversion.

[25]  S. Kahne,et al.  Optimal control: An introduction to the theory and ITs applications , 1967, IEEE Transactions on Automatic Control.

[26]  J. Carpentier,et al.  ‘To be or not to be modern’ that is the question for automatic generation control (point of view of a utility engineer) , 1985 .

[27]  Charles E. Fosha,et al.  The Megawatt-Frequency Control Problem: A New Approach Via Optimal Control Theory , 1970 .

[28]  M. Sanpei,et al.  Application of multi-variable control for automatic frequency controller of HVDC transmission system , 1994 .

[29]  Nathan Cohn,et al.  Considerations in the Regulation of Interconnected Areas , 1967 .

[30]  Mohammad Aldeen,et al.  Observability, controllability and decentralized control of interconnected power systems , 1991 .

[31]  Paul M. Julich,et al.  Models and performance functionals for load frequency control in interconnected power systems , 1971, CDC 1971.

[32]  Heinz Unbehauen,et al.  Design of a H/sub /spl infin//-optimal servo compensator for the frequency and voltage control of power plants , 1994, Proceedings of 1994 33rd IEEE Conference on Decision and Control.

[33]  Charles E. Fosha,et al.  Optimum Megawatt-Frequency Control of Multiarea Electric Energy Systems , 1970 .