BLM Analyzer: a software tool for experiments on planar lipid bilayers.

Planar lipid bilayers represent a versatile platform for studying the functions of various membrane proteins as well as the development of biosensors. Despite the continuing technological progress in the fabrication of low-noise bilayer setups with mechanically and electrically stable planar bilayers, there is still a lack of software utilities for assistance during bilayer formation. We present here a multipurpose software tool, the bilayer lipid membrane (BLM) Analyzer which performs high-resolution measurements of bilayer capacitance and resistance using saw-tooth voltage stimulation. Based on the measured values of capacitance and resistance, the BLM Analyzer detects formation, stabilization, and breakage of lipid bilayer, automatically selects appropriate stimulus protocol, compensates for voltage offsets, and issues sound and voice alerts informing about the state of the measurement cycle. The principle of the BLM Analyzer is based on the integration of current responses within four equivalent time segments. It provides capacitance estimates with standard deviation of several femtofarads at temporal resolution of several tens of milliseconds. The functions of the BLM Analyzer were tested experimentally by monitoring formation and thinning of planar lipid bilayer.

[1]  P. Novak,et al.  Q-Method for High-Resolution, Whole-Cell Patch-Clamp Impedance Measurements Using Square Wave Stimulation , 2006, Annals of Biomedical Engineering.

[2]  Toru Ide,et al.  A novel method for artificial lipid-bilayer formation. , 2005, Biosensors & bioelectronics.

[3]  P Novák,et al.  Computer-aided formation of the whole-cell patch-clamp recording configuration. , 2005, General physiology and biophysics.

[4]  George M Whitesides,et al.  Microfabricated teflon membranes for low-noise recordings of ion channels in planar lipid bilayers. , 2003, Biophysical journal.

[5]  B. Jena,et al.  SNAREs in opposing bilayers interact in a circular array to form conducting pores. , 2002, Biophysical journal.

[6]  H. Koepsell,et al.  An improved method for real-time monitoring of membrane capacitance in Xenopus laevis oocytes. , 2002, Biophysical journal.

[7]  F Bezanilla,et al.  Bilayer reconstitution of voltage-dependent ion channels using a microfabricated silicon chip. , 2001, Biophysical journal.

[8]  C. Trautmann,et al.  Microstructured glass chip for ion-channel electrophysiology. , 2001, Physical review. E, Statistical, nonlinear, and soft matter physics.

[9]  H. Bayley,et al.  Stochastic sensors inspired by biology , 2001, Nature.

[10]  K. Gillis,et al.  The noise of membrane capacitance measurements in the whole-cell recording configuration. , 2000, Biophysical journal.

[11]  C. Miller,et al.  Nystatin-induced liposome fusion. A versatile approach to ion channel reconstitution into planar bilayers. , 1990, Biophysical journal.

[12]  R J French,et al.  Optimizing planar lipid bilayer single-channel recordings for high resolution with rapid voltage steps. , 1990, Biophysical journal.

[13]  K. Gillis Techniques for Membrane Capacitance Measurements , 1995 .