Computational study of the blood flow in three types of 3D hollow fiber membrane bundles.

The goal of this study is to develop a computational fluid dynamics (CFD) modeling approach to better estimate the blood flow dynamics in the bundles of the hollow fiber membrane based medical devices (i.e., blood oxygenators, artificial lungs, and hemodialyzers). Three representative types of arrays, square, diagonal, and random with the porosity value of 0.55, were studied. In addition, a 3D array with the same porosity was studied. The flow fields between the individual fibers in these arrays at selected Reynolds numbers (Re) were simulated with CFD modeling. Hemolysis is not significant in the fiber bundles but the platelet activation may be essential. For each type of array, the average wall shear stress is linearly proportional to the Re. For the same Re but different arrays, the average wall shear stress also exhibits a linear dependency on the pressure difference across arrays, while Darcy's law prescribes a power-law relationship, therefore, underestimating the shear stress level. For the same Re, the average wall shear stress of the diagonal array is approximately 3.1, 1.8, and 2.0 times larger than that of the square, random, and 3D arrays, respectively. A coefficient C is suggested to correlate the CFD predicted data with the analytical solution, and C is 1.16, 1.51, and 2.05 for the square, random, and diagonal arrays in this paper, respectively. It is worth noting that C is strongly dependent on the array geometrical properties, whereas it is weakly dependent on the flow field. Additionally, the 3D fiber bundle simulation results show that the three-dimensional effect is not negligible. Specifically, velocity and shear stress distribution can vary significantly along the fiber axial direction.

[1]  Tomas Bodnár,et al.  On the shear-thinning and viscoelastic effects of blood flow under various flow rates , 2011, Appl. Math. Comput..

[2]  Tao Zhang,et al.  Computational design and in vitro characterization of an integrated maglev pump-oxygenator. , 2009, Artificial organs.

[3]  Two-Dimensional Finite Element Model for Oxygen Transfer in Cross-Flow Hollow Fiber Membrane Artificial Lungs , 2001, The International journal of artificial organs.

[4]  Tao Zhang,et al.  Computational model-based design of a wearable artificial pump-lung for cardiopulmonary/respiratory support. , 2012, Artificial organs.

[5]  Xi-yun Lu,et al.  Non-Newtonian effects of blood flow on hemodynamics in distal vascular graft anastomoses. , 2006, Journal of biomechanics.

[6]  Akio Funakubo,et al.  Flow Vectorial Analysis in an Artificial Implantable Lung , 2003, ASAIO journal.

[7]  H Reul,et al.  Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics. , 2001, Artificial organs.

[8]  J. Tarbell,et al.  Modeling interstitial flow in an artery wall allows estimation of wall shear stress on smooth muscle cells. , 1995, Journal of biomechanical engineering.

[9]  Kit Yan Chan,et al.  Pulsatile flow and mass transport over an array of cylinders: gas transfer in a cardiac-driven artificial lung. , 2006, Journal of biomechanical engineering.

[10]  R T Schoephoerster,et al.  Effects of local geometry and fluid dynamics on regional platelet deposition on artificial surfaces. , 1993, Arteriosclerosis and thrombosis : a journal of vascular biology.

[11]  M. Xenos,et al.  Erratum to: Evaluation of Shear-Induced Platelet Activation Models Under Constant and Dynamic Shear Stress Loading Conditions Relevant to Devices , 2013, Annals of Biomedical Engineering.

[12]  Kiyotaka Sakai,et al.  Theoretical and Experimental Evaluation for Blood Pressure Drop and Oxygen Transfer Rate in Outside Blood Flow Membrane Oxygenator , 1999 .

[13]  Guido Van Nooten,et al.  Mass Transfer Characteristics of Artificial Lungs , 2001, ASAIO journal.

[14]  Hideki Fujioka,et al.  Pulsatile blood flow and gas exchange across a cylindrical fiber array. , 2007, Journal of biomechanical engineering.

[15]  Tao Zhang,et al.  A quantitative comparison of mechanical blood damage parameters in rotary ventricular assist devices: shear stress, exposure time and hemolysis index. , 2012, Journal of biomechanical engineering.

[16]  Bartley P. Griffith,et al.  Characterization of membrane blood oxygenation devices using computational fluid dynamics , 2007 .

[17]  Goodarz Ahmadi,et al.  Uniformity of the fluid flow velocities within hollow fiber membranes of blood oxygenation devices. , 2006, Artificial organs.

[18]  R. Wolfe,et al.  Relationship of dose of hemodialysis and cause-specific mortality. , 1996, Kidney international.

[19]  Binbing Han,et al.  Mass and momentum transfer in hollow fibre blood oxygenators , 2002 .

[20]  Gabriele Dubini,et al.  Modeling evaluation of the fluid-dynamic microenvironment in tissue-engineered constructs: a micro-CT based model. , 2006, Biotechnology and bioengineering.

[21]  B. Griffith,et al.  Results of an artificial-lung survey to lung transplant program directors. , 2002, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[22]  Kiyotaka Sakai,et al.  Oxygen transfer performance of a membrane oxygenator composed of crossed and parallel hollow fibers , 2005 .

[23]  J. Grotberg,et al.  Pulsatile flow and oxygen transport past cylindrical fiber arrays for an artificial lung: computational and experimental studies. , 2008, Journal of biomechanical engineering.

[24]  J. Grotberg,et al.  Oxygen and carbon dioxide transport in time-dependent blood flow past fiber rectangular arrays , 2009 .

[25]  Shmuel Einav,et al.  Device Thrombogenicity Emulator (DTE)--design optimization methodology for cardiovascular devices: a study in two bileaflet MHV designs. , 2010, Journal of biomechanics.

[26]  H. Reul,et al.  Estimation of Shear Stress-related Blood Damage in Heart Valve Prostheses - in Vitro Comparison of 25 Aortic Valves , 1990, The International journal of artificial organs.

[27]  J. Grotberg,et al.  Pulsatile flow and mass transport past a circular cylinder , 2006 .

[28]  Nelson O. Moraga,et al.  On predicting unsteady non-Newtonian blood flow , 2005, Appl. Math. Comput..

[29]  J D Hellums,et al.  Red blood cell damage by shear stress. , 1972, Biophysical journal.

[30]  John M. Tarbell,et al.  Effect of Fluid Flow on Smooth Muscle Cells in a 3-Dimensional Collagen Gel Model , 2000, Arteriosclerosis, thrombosis, and vascular biology.

[31]  K. Kuwana,et al.  Comparison of a new heparin-coated dense membrane lung with nonheparin-coated dense membrane lung for prolonged extracorporeal lung assist in goats. , 2004, Artificial organs.

[32]  Kiyotaka Sakai,et al.  Blood flow and oxygen transfer rate of an outside blood flow membrane oxygenator , 2000 .

[33]  K. Gage,et al.  Modeling flow effects on thrombotic deposition in a membrane oxygenator. , 2000, Artificial organs.

[34]  K. Fraser,et al.  Micro-scale Modeling of Flow and Oxygen Transfer in Hollow Fiber Membrane Bundle. , 2010, Journal of membrane science.

[37]  H. Lugt,et al.  Laminar flow behavior under slip−boundary conditions , 1975 .

[38]  J. Grotberg,et al.  Pulsatile blood flow and oxygen transport past a circular cylinder. , 2007, Journal of biomechanical engineering.

[39]  William R Wagner,et al.  Predicting membrane oxygenator pressure drop using computational fluid dynamics. , 2002, Artificial organs.

[40]  W. Federspiel,et al.  Modeling of Blood Flow in a Balloon-Pulsed Intravascular Respiratory Catheter , 2007, ASAIO journal.

[41]  Pascal Verdonck,et al.  Numerical calculation of hemolysis levels in peripheral hemodialysis cannulas. , 2002, Artificial organs.