Electrode characterization for functional application to upper extremity FNS

A quantitative method has been developed to characterize the isometric vectors of electrically simulated paralyzed muscles of the thumb. The vectorial force output as a function of the stimulus level was measured for individual electrode/muscle combinations in a number of intramuscular and epimysial electrodes implanted in paralyzed thenar of cervical-level spinal-cord-injury subjects. Vectors were used to determine the output characteristics of each electrode/muscle combination. The characteristics studied included the strength of the contraction, the stimulus level at which fibers from other muscles are stimulated, the recruitment gain of force, dependency of the output on the skeletal position, and the direction of force produced.<<ETX>>

[1]  L. Vodovnik,et al.  Proportionally controlled functional electrical stimulation of hand. , 1973, Archives of physical medicine and rehabilitation.

[2]  Stauffer Es Diagnosis and prognosis of acute cervical spinal cord injury. , 1975 .

[3]  P H Peckham,et al.  Upper and lower motor neuron lesions in the upper extremity muscles of tetraplegics , 1976, Paraplegia.

[4]  E. Marsolais,et al.  Alteration in the force and fatigability of skeletal muscle in quadriplegic humans following exercise induced by chronic electrical stimulation. , 1976, Clinical orthopaedics and related research.

[5]  E. Marsolais,et al.  Restoration of key grip and release in the C6 tetraplegic patient through functional electrical stimulation. , 1980 .

[6]  P. Crago,et al.  Modulation of Muscle Force by Recruitment During Intramuscular Stimulation , 1980, IEEE Transactions on Biomedical Engineering.

[7]  P. H. Peckham FUNCTIONAL NEUROMUSCULAR STIMULATION. , 1981 .

[8]  P. Hunter Peckham,et al.  Multichannel Implantable Stimulator for Control of Paralyzed Muscle , 1981, IEEE Transactions on Biomedical Engineering.

[9]  M. Keith,et al.  COORDINATED TWO MODE GRASP IN THE QUADRIPLEGIC INITIATED BY FUNCTIONAL NEUROMUSCULAR STIMULATION , 1983 .

[10]  R. Nathan The development of a computerized upper limb electrical stimulation system. , 1984, Orthopedics.

[11]  An apparatus making possible restoration of simple functions of the tetraplegic hand , 1984, Paraplegia.

[12]  Paul W. Brand,et al.  Clinical mechanics of the hand , 1985 .

[13]  Dennis D. Roscoe,et al.  An Externally Powered, Multichannel, Implantable Stimulator for Versatile Control of Paralyzed Muscle , 1987, IEEE Transactions on Biomedical Engineering.

[14]  M. Keith,et al.  Functional neuromuscular stimulation neuroprostheses for the tetraplegic hand. , 1988, Clinical orthopaedics and related research.

[15]  K. Kilgore,et al.  Implantable functional neuromuscular stimulation in the tetraplegic hand. , 1989, The Journal of hand surgery.