Thermal performance of a heating system working with a PCM plate heat exchanger and comparison with a water tank

Abstract Heat storage equipment plays a very important role in micro-cogeneration plants as unconsumed heat can be released when needed. PCM heat exchangers are an alternative to commonly used storage tanks. Moreover, PCM heat exchangers occupy less space for the same amount of stored energy. This paper examines the energy performance of a heating-power micro-cogeneration system applied to a 450 m 2 office space. A hot water thermal energy storage system and two latent heat thermal energy storage systems based on PCM plate heat exchangers are compared and their performances are analyzed under dynamic conditions. Operating strategies for the PCM heat exchanger and water tank are discussed in terms of the heat demand and power supplied by the internal combustion engine of a micro-CHP system. The thermal performance of two possible PCMs: RT60 paraffin and Palmitic Acid, in the form of plates inside the heat exchanger, are analyzed under processes of charging (PCM melting) and discharging (PCM solidification). Charge and discharge duration as well as the capability to deliver the appropriate heat transfer rate are compared. Palmitic Acid provides better results, with higher heat transfer rates, more accumulated energy and less storage units needed to meet the heating demand.

[1]  A. Campos-Celador,et al.  Design of a Finned Plate Latent Heat Thermal Energy Storage System for Domestic Applications , 2014 .

[2]  Luisa F. Cabeza,et al.  Numerical model evaluation of a PCM cold storage tank and uncertainty analysis of the parameters , 2014 .

[3]  Carlo Roselli,et al.  Influence of climatic conditions and control logic on NOx and CO emissions of a micro-cogeneration unit serving an Italian residential building , 2014 .

[4]  V. Ismet Ugursal,et al.  An investigation of the techno-economic impact of internal combustion engine based cogeneration systems on the energy requirements and greenhouse gas emissions of the Canadian housing stock , 2015 .

[5]  J. Payá,et al.  Performance characterization of a PCM storage tank , 2014 .

[6]  V. Voller,et al.  A fixed grid numerical modelling methodology for convection-diffusion mushy region phase-change problems , 1987 .

[7]  Dongxu Wang,et al.  System design and energy performance of a solar heat pump heating system with dual-tank latent heat storage , 2015 .

[8]  Takayuki Matsunuma,et al.  Micro gas turbine cogeneration system with latent heat storage at the University: Part II: Part load and thermal priority mode , 2014 .

[9]  Luisa F. Cabeza,et al.  Comparative analysis of latent thermal energy storage tanks for micro-CHP systems , 2013 .

[10]  Wasim Saman,et al.  Validation of a mathematical model for encapsulated phase change material flat slabs for cooling applications , 2011 .

[11]  David Diarra,et al.  Assessment of primary energy savings by means of CHP systems in domestic energy supply , 2014 .

[12]  Arun S. Mujumdar,et al.  Numerical study on melting of paraffin wax with Al2O3 in a square enclosure , 2012 .

[13]  Takayuki Matsunuma,et al.  Micro gas turbine cogeneration system with latent heat storage at the University: Part I: Plan and energy flow test , 2014 .

[14]  I. Suárez,et al.  A FAST NUMERICAL MODEL TO CALCULATE THE THERMAL PERFORMANCE OF A HEAT EXCHANGER WITH RECTANGULAR PCM STORAGE , 2014 .

[15]  Study of the density and viscosity of some pure fatty acids. , 1999 .

[16]  R. K. Sharma,et al.  Developments in organic solid–liquid phase change materials and their applications in thermal energy storage , 2015 .

[17]  Luisa F. Cabeza,et al.  PCM thermal energy storage tanks in heat pump system for space cooling , 2014 .

[18]  Giorgio Graditi,et al.  Technical and cost analyses of two different heat storage systems for residential micro-CHP plants , 2014 .

[19]  Wasim Saman,et al.  Thermal performance analysis of a flat slab phase change thermal storage unit with liquid-based heat transfer fluid for cooling applications , 2011 .

[20]  Kamaruzzaman Sopian,et al.  CFD applications for latent heat thermal energy storage: a review , 2013 .

[21]  Fariborz Haghighat,et al.  Integration of PCM in Domestic Hot Water Tanks: Optimization for Shifting Peak Demand , 2015 .

[22]  Lieve Helsen,et al.  The impact of thermal storage on the operational behaviour of residential CHP facilities and the overall CO2 emissions , 2007 .

[23]  M. M. Prieto,et al.  Measurements of temperature and melting heat of some pure fatty acids and their binary and ternary mixtures by differential scanning calorimetry , 2001 .

[24]  Graham Coates,et al.  Sizing of residential CHP systems , 2011 .

[25]  Takayuki Matsunuma,et al.  Micro gas turbine cogeneration system with latent heat storage at the University: Part III: Temperature control schedule , 2014 .

[26]  J. A. Huidobro,et al.  Viscosities of Binary and Ternary Mixtures of Hexadecanoic, Octadecanoic, and cis-9-Octadecenoic Acids , 2000 .

[27]  F. O. Cedeño,et al.  Measurements and Estimate of Heat Capacity for Some Pure Fatty Acids and Their Binary and Ternary Mixtures , 2000 .

[28]  Estudio de la densidad y de la viscosidad de algunos ácidos grasos puros , 1999 .

[29]  Hongbo Ren,et al.  Economic and environmental evaluation of micro CHP systems with different operating modes for residential buildings in Japan , 2010 .

[30]  L. Cabeza,et al.  Experimental evaluation of commercial heat exchangers for use as PCM thermal storage systems , 2009 .

[31]  Carlo Roselli,et al.  Load sharing with a local thermal network fed by a microcogenerator: Thermo-economic optimization by means of dynamic simulations , 2014 .