Erratum: “Magnetic hysteresis and magnetic flux patterns measured by acoustically stimulated electromagnetic response in a steel plate”

Magnetic hysteresis loops are measured by ultrasonic techniques and used in visualizing the magnetic-flux distribution in a steel plate. The piezomagnetic coefficient determines the amplitude of acoustically stimulated electromagnetic (ASEM) fields, yielding the hysteresis behavior of the intensity of the ASEM response. By utilizing the high correspondence of the ASEM response to the magnetic-flux density, we image the specific spatial patterns of the flux density formed by an artificial defect in a steel plate specimen. Magnetic-flux probing by ultrasonic waves is thus shown to be a viable method of nondestructive material inspection.