Scatterer size-based analysis of optical coherence tomography images using spectral estimation techniques.

A novel spectral analysis technique of OCT images is demonstrated in this paper for classification and scatterer size estimation. It is based on SOCT autoregressive spectral estimation techniques and statistical analysis. Two different statistical analysis methods were applied to OCT images acquired from tissue phantoms, the first method required prior information on the sample for variance analysis of the spectral content. The second method used k-means clustering without prior information for the sample. The results are very encouraging and indicate that the spectral content of OCT signals can be used to estimate scatterer size and to classify dissimilar areas in phantoms and tissues with sensitivity and specificity of more than 90%.

[1]  J. MacQueen Some methods for classification and analysis of multivariate observations , 1967 .

[2]  M Fitzmaurice,et al.  Endoscopic detection of dysplasia in patients with Barrett's esophagus using light-scattering spectroscopy. , 2000, Gastroenterology.

[3]  J Beuthan,et al.  The spatial variation of the refractive index in biological cells. , 1996, Physics in medicine and biology.

[4]  Adam Wax,et al.  Temporal coherence and time-frequency distributions in spectroscopic optical coherence tomography. , 2007, Journal of the Optical Society of America. A, Optics, image science, and vision.

[5]  M. Insana,et al.  Autoregressive spectral estimation in ultrasonic scatterer size imaging. , 1996, Ultrasonic imaging.

[6]  Chenyang Xu,et al.  Wavelength-dependent scattering in spectroscopic optical coherence tomography. , 2005, Optics express.

[7]  Xin Qi,et al.  Computer-aided diagnosis of dysplasia in Barrett's esophagus using endoscopic optical coherence tomography. , 2006, Journal of biomedical optics.

[8]  J. Fujimoto,et al.  Spectroscopic optical coherence tomography. , 2000 .

[9]  Ton G van Leeuwen,et al.  Light absorption of (oxy-)hemoglobin assessed by spectroscopic optical coherence tomography. , 2003, Optics letters.

[10]  Daniel L Marks,et al.  Near-infrared dyes as contrast-enhancing agents for spectroscopic optical coherence tomography. , 2004, Optics letters.

[11]  Andrew K. Dunn,et al.  Three-dimensional computation of light scattering from cells , 1996 .

[12]  Stephen A. Boppart,et al.  Comparative performance analysis of time–frequency distributions for spectroscopic optical coherence tomography , 2005 .

[13]  Cheng-Lun Tsai,et al.  Near-infrared Absorption Property of Biological Soft Tissue Constituents , 2001 .

[14]  Chenyang Xu,et al.  Spectroscopic Optical Coherence Tomography and Microscopy , 2007, IEEE Journal of Selected Topics in Quantum Electronics.

[15]  R. F. Wagner,et al.  A comparison of autoregressive spectral estimation algorithms and order determination methods in ultrasonic tissue characterization , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  Stephen A. Boppart,et al.  Light-scattering spectroscopic optical coherence tomography for differentiating cells in 3D cell culture , 2006, SPIE BiOS.

[17]  Stephen A. Boppart,et al.  Optical Coherence Tomography , 2020, Imaging from Cells to Animals In Vivo.

[18]  Murray H Loew,et al.  Computer recognition of cancer in the urinary bladder using optical coherence tomography and texture analysis. , 2008, Journal of biomedical optics.

[19]  M. Sivak,et al.  Computer-aided diagnosis of dysplasia in Barrett's esophagus using endoscopic optical coherence tomography. , 2006 .

[20]  Rebecca Richards-Kortum,et al.  Novel algorithm of processing optical coherence tomography images for differentiation of biological tissue pathologies. , 2005, Journal of biomedical optics.

[21]  Nicholas Stone,et al.  Near real-time classification of optical coherence tomography data using principal components fed linear discriminant analysis. , 2008, Journal of biomedical optics.

[22]  Michael B. Wallace,et al.  Observation of periodic fine structure in reflectance from biological tissue: A new technique for measuring nuclear size distribution , 1998 .

[23]  James Fujimoto,et al.  Optical coherence tomography contrast enhancement using spectroscopic analysis with spectral autocorrelation. , 2004, Optics express.

[24]  Joseph A Izatt,et al.  Fourier-domain low-coherence interferometry for light-scattering spectroscopy. , 2003, Optics letters.

[25]  S. Shapshay,et al.  Detection of preinvasive cancer cells , 2000, Nature.

[26]  W Drexler,et al.  Precision of extracting absorption profiles from weakly scattering media with spectroscopic time-domain optical coherence tomography. , 2004, Optics express.

[27]  Michael S. Feld,et al.  Measuring cellular structure at submicrometer scale with light scattering spectroscopy , 2001 .

[28]  Victoria J Allan,et al.  Light Microscopy Techniques for Live Cell Imaging , 2003, Science.

[29]  Changhuei Yang,et al.  Determination of particle size by using the angular distribution of backscattered light as measured with low-coherence interferometry. , 2002, Journal of the Optical Society of America. A, Optics, image science, and vision.

[30]  Evgenia Bousi,et al.  AM–FM techniques in the analysis of optical coherence tomography signals , 2009, Journal of biophotonics.