HBD layout isolation techniques for multiple node charge collection mitigation

A three-dimensional (3D) technology computer-aided design (TCAD) model was used to simulate charge collection at multiple nodes. Guard contacts are shown to mitigate the charge collection and to more quickly restore the well potential, especially in PMOS devices. Mitigation of the shared charge collection in NMOS devices is accomplished through isolation of the P-wells using a triple-well option. These techniques have been partially validated through heavy-ion testing of three versions of flip-flop shift register chains.

[1]  T. Calin,et al.  Upset hardened memory design for submicron CMOS technology , 1996 .

[2]  P. Eaton,et al.  Soft error rate mitigation techniques for modern microcircuits , 2002, 2002 IEEE International Reliability Physics Symposium. Proceedings. 40th Annual (Cat. No.02CH37320).