Analytic and quantitative exposition of patient-specific systematic inaccuracies inherent in planar DXA-derived in vivo BMD measurements.

An extensive analytic exposition is developed of systematic inaccuracies inherent in planar dual-energy x-ray absorptiometry (DXA) in vivo bone mineral density (BMD) measurements arising directly from the dual-energy facet of this methodology. Generalized and specific criteria governing these BMD inaccuracies are derived for the presence of relevant absorptiometrically distinguishable extra- and intra-osseous soft tissues (lean muscle tissue, interposed adipose, marrow, and cerebrospinal fluid). These analytic findings are utilized in comprehensive quantitative simulation studies which evaluate the magnitude and stipulate the direction (under- or over-estimate) of such systematic errors for typical, realistic DXA in vivo lumbar vertebral BMD scans over the ranges of soft tissue parameters and trabecular bone volumes (TBV) encountered clinically. It is shown that inherent systematic inaccuracies as high as +/- approximately 20% may be anticipated in typical patient-specific planar DXA vertebral BMD scans, particularly so for older, osteoporotic-prone, and osteoporotic individuals. These inaccuracies exceed considerably the DXA precision error and may mask or exaggerate clinically significant true changes in BMD. Both the scale and trends of patient-specific inaccuracies found to pertain in the present work are in keeping with those observed by recent investigators in actual specimen-specific in situ and in vitro DXA scans of given cadaveric bones. Insofar as the range of BMD inaccuracies found here is comparable to that of variations in the DXA-measured interpatient, age-moderated BMD of normal individuals, the intrinsic specificity of planar DXA for screening/diagnostic purposes is examined critically. It is shown that these inherent inaccuracies may prompt erroneous diagnoses, assessments, and interpretations of DXA-derived BMD measurements undertaken to screen, monitor, and help evaluate patient-specific predictive bone fragility, and to assess the efficacy of drug and other therapeutic regimens.

[1]  T. Hangartner,et al.  Influence of fat on bone measurements with dual-energy absorptiometry. , 1990, Bone and mineral.

[2]  J A Sorenson,et al.  Simulation studies of dual-energy x-ray absorptiometry. , 1989, Medical physics.

[3]  J A Sorenson Effects of nonmineral tissues on measurement of bone mineral content by dual-photon absorptiometry. , 1990, Medical physics.

[4]  M M Goodsitt,et al.  The Composition of Bone Marrow for a Dual-Energy Quantitative Computed Tomography Technique: A Cadaver and Computer Simulation Study , 1994, Investigative radiology.

[5]  W A Kalender,et al.  A phantom for standardization and quality control in spinal bone mineral measurements by QCT and DXA: design considerations and specifications. , 1992, Medical physics.

[6]  M M Goodsitt,et al.  Evaluation of a new set of calibration standards for the measurement of fat content via DPA and DXA. , 1992, Medical physics.

[7]  H. Wahner,et al.  The evaluation of osteoporosis : dual energy x-ray absorptiometry in clinical practice , 1994 .

[8]  K.,et al.  Differential changes in bone mineral density of the appendicular and axial skeleton with aging: relationship to spinal osteoporosis. , 1981, The Journal of clinical investigation.

[9]  J. Glowacki Influence of age on human marrow. , 1995, Calcified tissue international.

[10]  P. Tothill Methods of bone mineral measurement. , 1989, Physics in medicine and biology.

[11]  P. Tothill,et al.  Errors due to non-uniform distribution of fat in dual X-ray absorptiometry of the lumbar spine. , 1992, The British journal of radiology.

[12]  I. Cullum,et al.  X-ray dual-photon absorptiometry: a new method for the measurement of bone density. , 1989, The British journal of radiology.

[13]  Richard L. P. Custer,et al.  An Atlas of the Blood and Bone Marrow , 1974 .

[14]  D. R. White,et al.  The composition of body tissues. , 1986, The British journal of radiology.

[15]  G. Blake,et al.  Dual energy x-ray absorptiometry: the effects of beam hardening on bone density measurements. , 1992, Medical physics.

[16]  J. H. Hubbell,et al.  Photon mass attenuation and energy-absorption coefficients , 1982 .

[17]  D. Sartoris,et al.  Accuracy of dual-energy radiographic absorptiometry of the lumbar spine: cadaver study. , 1990, Radiology.

[18]  H W Wahner,et al.  Changes in bone mineral density of the proximal femur and spine with aging. Differences between the postmenopausal and senile osteoporosis syndromes. , 1982, The Journal of clinical investigation.

[19]  A. Rahmouni,et al.  Normal age-related patterns of cellular and fatty bone marrow distribution in the axial skeleton: MR imaging study. , 1990, Radiology.

[20]  P. Tothill,et al.  Precision and accuracy of measurements of whole-body bone mineral: comparisons between Hologic, Lunar and Norland dual-energy X-ray absorptiometers. , 1994, The British journal of radiology.