Action Sport Cameras as an Instrument to Perform a 3D Underwater Motion Analysis

Action sport cameras (ASC) are currently adopted mainly for entertainment purposes but their uninterrupted technical improvements, in correspondence of cost decreases, are going to disclose them for three-dimensional (3D) motion analysis in sport gesture study and athletic performance evaluation quantitatively. Extending this technology to sport analysis however still requires a methodologic step-forward to making ASC a metric system, encompassing ad-hoc camera setup, image processing, feature tracking, calibration and 3D reconstruction. Despite traditional laboratory analysis, such requirements become an issue when coping with both indoor and outdoor motion acquisitions of athletes. In swimming analysis for example, the camera setup and the calibration protocol are particularly demanding since land and underwater cameras are mandatory. In particular, the underwater camera calibration can be an issue affecting the reconstruction accuracy. In this paper, the aim is to evaluate the feasibility of ASC for 3D underwater analysis by focusing on camera setup and data acquisition protocols. Two GoPro Hero3+ Black (frequency: 60Hz; image resolutions: 1280×720/1920×1080 pixels) were located underwater into a swimming pool, surveying a working volume of about 6m3. A two-step custom calibration procedure, consisting in the acquisition of one static triad and one moving wand, carrying nine and one spherical passive markers, respectively, was implemented. After assessing camera parameters, a rigid bar, carrying two markers at known distance, was acquired in several positions within the working volume. The average error upon the reconstructed inter-marker distances was less than 2.5mm (1280×720) and 1.5mm (1920×1080). The results of this study demonstrate that the calibration of underwater ASC is feasible enabling quantitative kinematic measurements with accuracy comparable to traditional motion capture systems.

[1]  M Arcan,et al.  Biomechanical analysis of the three-dimensional foot structure during gait: a basic tool for clinical applications. , 2000, Journal of biomechanical engineering.

[2]  Matthew A. Timmis,et al.  Visual Search Strategies of Soccer Players Executing a Power vs. Placement Penalty Kick , 2014, PloS one.

[3]  Claudio Cobelli,et al.  Markerless analysis of front crawl swimming. , 2011, Journal of biomechanics.

[4]  George T. Gillies,et al.  Kinematic analysis of the gait of adult sheep during treadmill locomotion: Parameter values, allowable total error, and potential for use in evaluating spinal cord injury , 2015, Journal of the Neurological Sciences.

[5]  Pietro Cerveri,et al.  Quantitative underwater 3D motion analysis using submerged video cameras: accuracy analysis and trajectory reconstruction , 2013, Computer methods in biomechanics and biomedical engineering.

[6]  Tomislav Pribanić,et al.  CALIBRATION OF 3D KINEMATIC SYSTEMS USING 2D CALIBRATION PLATE , 2008 .

[7]  A. Leardini,et al.  Effects of frontal and sagittal thorax attitudes in gait on trunk and pelvis three-dimensional kinematics. , 2015, Medical engineering & physics.

[8]  Nathaniel A Bates,et al.  Impact differences in ground reaction force and center of mass between the first and second landing phases of a drop vertical jump and their implications for injury risk assessment. , 2013, Journal of biomechanics.

[9]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 2: instrumental errors. , 2004, Gait & posture.

[10]  Silvia Fantozzi,et al.  Effectiveness of an automatic tracking software in underwater motion analysis. , 2013, Journal of sports science & medicine.

[11]  Alberto E. Minetti,et al.  Shoulder 3D range of motion and humerus rotation in two volleyball spike techniques: injury prevention and performance , 2015, Sports biomechanics.

[12]  Caterina Balletti,et al.  Calibration of Action Cameras for Photogrammetric Purposes , 2014, Sensors.

[13]  Kelly de Jesus,et al.  Reconstruction Accuracy Assessment of Surface and Underwater 3D Motion Analysis: A New Approach , 2015, Comput. Math. Methods Medicine.

[14]  J G Hay,et al.  Three-dimensional videography of swimming with panning periscopes. , 1996, Journal of biomechanics.

[15]  Emil Olsen,et al.  Accuracy and Precision of Equine Gait Event Detection during Walking with Limb and Trunk Mounted Inertial Sensors , 2012, Sensors.

[16]  Claudio Cobelli,et al.  Motion analysis of front crawl swimming applying CAST technique by means of automatic tracking , 2013, Journal of sports sciences.

[17]  Oliver Rettig,et al.  Motion patterns in activities of daily living: 3- year longitudinal follow-up after total shoulder arthroplasty using an optical 3D motion analysis system , 2014, BMC Musculoskeletal Disorders.

[18]  S I Wolf,et al.  Motion capture of the upper extremity during activities of daily living in patients with spastic hemiplegic cerebral palsy. , 2013, Gait & posture.

[19]  Amador García-Ramos,et al.  Relationship between different push-off variables and start performance in experienced swimmers , 2015, European journal of sport science.

[20]  Pietro Cerveri,et al.  A 3D kinematic analysis of breathing patterns in competitive swimmers , 2012, Journal of sports sciences.

[21]  Patria A. Hume,et al.  SPRINT KAYAKING STROKE RATE RELIABILITY, VARIABILITY AND VALIDITY OF THE DIGITRAINER ACCELEROMETER COMPARED TO GOPRO VIDEO MEASUREMENT , 2012 .

[22]  Rezaul Begg,et al.  A multiple regression normalization approach to evaluation of gait in total knee arthroplasty patients. , 2016, Clinical biomechanics.

[23]  Jianhua Wang,et al.  A new calibration model of camera lens distortion , 2008, Pattern Recognit..

[24]  Mark Shortis,et al.  Calibration Techniques for Accurate Measurements by Underwater Camera Systems , 2015, Sensors.

[25]  Pietro Cerveri,et al.  ACCURACY OF SPORT ACTION CAMERAS FOR 3D UNDERWATER MOTION ANALYSIS , 2014 .

[26]  C. Cobelli,et al.  Comparison of Markerless and Marker-Based Motion Capture Technologies through Simultaneous Data Collection during Gait: Proof of Concept , 2014, PloS one.

[27]  Daniel Santana-Cedrés,et al.  Tracking futsal players with a wide-angle lens camera: accuracy analysis of the radial distortion correction based on an improved Hough transform algorithm , 2017, Comput. methods Biomech. Biomed. Eng. Imaging Vis..

[28]  Silvia Fantozzi,et al.  Gait Kinematic Analysis in Water Using Wearable Inertial Magnetic Sensors , 2015, PloS one.

[29]  Panagiotis Kasimatis,et al.  Reconstruction accuracy in underwater three-dimensional kinematic analysis. , 2008, Journal of science and medicine in sport.

[30]  Ricardo M. L. Barros,et al.  A flexible software for tracking of markers used in human motion analysis , 2003, Comput. Methods Programs Biomed..

[31]  Albert K. Chong,et al.  Low‐cost compact cameras: a medical application in CMT disease monitoring , 2011 .

[32]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 1: theoretical background. , 2005, Gait & posture.

[33]  Young-Hoo Kwon,et al.  APPLICABILITY OF FOUR LOCALIZED-CALIBRATION METHODS IN UNDERWATER MOTION ANALYSIS , 2000 .

[34]  Pietro Cerveri,et al.  Combined evolution strategies for dynamic calibration of video-based measurement systems , 2001, IEEE Trans. Evol. Comput..

[35]  A Pedotti,et al.  Complete calibration of a stereo photogrammetric system through control points of unknown coordinates. , 1998, Journal of biomechanics.

[36]  K. Ball,et al.  Three-dimensional trunk kinematics in golf: between-club differences and relationships to clubhead speed , 2013, Sports biomechanics.

[37]  Motoki Kouzaki,et al.  Anticipation by basketball defenders: An explanation based on the three-dimensional inverted pendulum model , 2014, European journal of sport science.

[38]  Zhengyou Zhang,et al.  A Flexible New Technique for Camera Calibration , 2000, IEEE Trans. Pattern Anal. Mach. Intell..

[39]  Pietro Cerveri,et al.  Comparison of different camera calibration approaches for underwater applications. , 2012, Journal of biomechanics.

[40]  Laurent David,et al.  Measurement of three-dimensional hand kinematics during swimming with a motion capture system: a feasibility study , 2014 .

[41]  J. Richards,et al.  Three-dimensional kinematic comparison of treadmill and overground running , 2013, Sports biomechanics.