Optimal Design of Point-Focusing Shear Vertical Wave Electromagnetic Ultrasonic Transducers Based on Orthogonal Test Method

The lower conversion efficiency is the main drawback of electromagnetic acoustic transducers (EMATs) compared with other transducers, which limits their use in many industrial applications. In this paper, for enhancing the performance of point-focusing shear vertical wave EMATs (PFSV-EMATs), 18 orthogonal tests with seven factors and three levels are conducted through finite-element simulations. First, the degree of seven factors on the signal amplitude, axial focus offset, and radial focus offset is obtained by range analysis and compared. It indicates that the effect of the liftoff distance and the exciting current on signal amplitude is the largest, while the effect of the inner radius of concentric meander-line coils on the axial and radial focal offset is the largest. Then, the influence degree of various factors on test results is analyzed at frequencies of 1.5, 2, and 2.5 MHz, showing that the relatively low frequency, i.e., the sparser coil spacing, is favorable for signal amplitude and detrimental for point-focusing ability. Finally, experiments are carried out to verify the validation of optimization results, which indicates that the increased signal amplitude of 88.78%, smaller axial focus offset, and zero radial focus offset can be achieved by the optimized PFSV-EMAT, which has the improved signal amplitude and point-focusing behavior, compared with the non-optimized one.

[1]  Peter Cawley,et al.  Study and comparison of different EMAT configurations for SH wave inspection , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  K. Grattan,et al.  A model for pulsed Rayleigh wave and optimal EMAT design , 2006 .

[3]  Katsuhiro Kawashima,et al.  Theory and numerical calculation of the acoustic field produced in metal by an electromagnetic ultrasonic transducer , 1976 .

[4]  Hong Min Seung,et al.  An omnidirectional shear-horizontal guided wave EMAT for a metallic plate. , 2016, Ultrasonics.

[5]  Lei Kang,et al.  Optimal Design of Lamb Wave Electromagnetic Acoustic Transducers for Improving Their Excitation Performance , 2011 .

[6]  P. Cawley,et al.  Omnidirectional guided wave inspection of large metallic plate structures using an EMAT array , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  Hirotsugu Ogi,et al.  Development of shear-vertical-wave point-focusing electromagnetic acoustic transducer , 2015 .

[8]  Anthony N. Sinclair,et al.  Optimal design of EMAT transmitters , 2004 .

[9]  Rachel S. Edwards,et al.  Shear wave generation using a spiral electromagnetic acoustic transducer , 2006 .

[10]  Steve Dixon,et al.  High temperature thickness measurements of stainless steel and low carbon steel using electromagnetic acoustic transducers , 2014 .

[11]  Stuart B. Palmer,et al.  Industrially viable non-contact ultrasound , 2003 .

[12]  Zhenmao Chen,et al.  A modified meander-line-coil EMAT design for signal amplitude enhancement , 2016 .

[13]  S. Dixon,et al.  High temperature EMAT design for scanning or fixed point operation on magnetite coated steel , 2017 .

[14]  Rachel S. Edwards,et al.  Focused Rayleigh wave EMAT for characterisation of surface-breaking defects , 2016 .

[15]  Chao Zhang,et al.  Enhancement of ultrasonic signal using a new design of Rayleigh-wave electromagnetic acoustic transducer , 2017 .

[16]  Frederic Cegla,et al.  Optimization of the Bias Magnetic Field of Shear Wave EMATs , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[17]  Songling Huang,et al.  A multi‐objective structural optimization of an omnidirectional electromagnetic acoustic transducer , 2017, Ultrasonics.

[18]  S Dixon,et al.  Coupling mechanism of an EMAT. , 2006, Ultrasonics.

[19]  P. Cawley,et al.  A two-dimensional Fourier transform method for the measurement of propagating multimode signals , 1991 .

[20]  Jinyong Peng,et al.  Orthogonal test design for optimization of supercritical fluid extraction of daphnoretin, 7-methoxy-daphnoretin and 1,5-diphenyl-1-pentanone from Stellera chamaejasme L. and subsequent isolation by high-speed counter-current chromatography. , 2006, Journal of chromatography. A.

[21]  H. Ogi,et al.  Line-focusing electromagnetic acoustic transducers for the detection of slit defects , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  D. MacLauchlan,et al.  RECENT ADVANCEMENTS IN THE APPLICATION OF EMATS TO NDE , 2004 .

[23]  F Cegla,et al.  EMAT phased array: A feasibility study of surface crack detection , 2017, Ultrasonics.

[24]  H. Ogi,et al.  EMATs for Science and Industry: Noncontacting Ultrasonic Measurements , 2010 .

[25]  Guofu Zhai,et al.  Numerical and experimental analysis of unidirectional meander-line coil electromagnetic acoustic transducers , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[26]  Shixiang Xia,et al.  The application of orthogonal test method in the parameters optimization of PEMFC under steady working condition , 2016 .

[27]  Shen Wang,et al.  Multiphysics Modeling of a Lorentz Force-Based Meander Coil Electromagnetic Acoustic Transducer via Steady-State and Transient Analyses , 2016, IEEE Sensors Journal.