Vascular MR segmentation: wall and plaque

Cardiovascular events frequently result from local rupture of vulnerable atherosclerotic plaque. Non-invasive assessment of plaque vulnerability is needed to allow institution of preventive measures before heart attack or stroke occur. A computerized method for segmentation of arterial wall layers and plaque from high-resolution volumetric MR images is reported. The method uses dynamic programming to detect optimal borders in each MRI frame. The accuracy of the results was tested in 62 T1-weighted MR images from 6 vessel specimens in comparison to borders manually determined by an expert observer. The mean signed border positioning errors for the lumen, internal elastic lamina, and external elastic lamina borders were -0.12±0.14 mm, 0.04±0.12mm, and -0.15±0.13 mm, respectively. The presented wall layer segmentation approach is one of the first steps towards non-invasive assessment of plaque vulnerability in atherosclerotic subjects.

[1]  Samin K. Sharma,et al.  Noninvasive in vivo human coronary artery lumen and wall imaging using black-blood magnetic resonance imaging. , 2000, Circulation.

[2]  R. Lauer,et al.  Increased familial cardiovascular mortality in obese schoolchildren: the Muscatine Ponderosity Family Study. , 1992, Pediatrics.

[3]  E J Topol,et al.  Coronary morphologic and clinical determinants of procedural outcome with angioplasty for multivessel coronary disease. Implications for patient selection. Multivessel Angioplasty Prognosis Study Group. , 1990, Circulation.

[4]  W R Clarke,et al.  Use of cholesterol measurements in childhood for the prediction of adult hypercholesterolemia. The Muscatine Study. , 1990, JAMA.

[5]  M. Sonka,et al.  Fusion of angiography and intravascular ultrasound in vivo: establishing the absolute 3-D frame orientation , 1999, IEEE Transactions on Biomedical Engineering.

[6]  M. S. Williams,et al.  Stent and artery geometry determine intimal thickening independent of arterial injury. , 2000, Circulation.

[7]  R. Ogden,et al.  A New Constitutive Framework for Arterial Wall Mechanics and a Comparative Study of Material Models , 2000 .

[8]  Milan Sonka,et al.  Image Processing, Analysis and Machine Vision , 1993, Springer US.

[9]  Vincenzo Ciampi,et al.  M. A. Crisfield, Non-linear Finite Element Analysis of Solids and Structures , 1997 .

[10]  F Alfonso,et al.  Propensity and mechanisms of restenosis in different coronary stent designs: complementary value of the analysis of the luminal gain-loss relationship. , 1999, Journal of the American College of Cardiology.

[11]  Mike Otto,et al.  Discrimination of early/intermediate and advanced/complicated coronary plaque types by radiofrequency intravascular ultrasound analysis. , 2002, The American journal of cardiology.

[12]  Milan Sonka,et al.  Image segmentation and tissue characterization in intravascular ultrasound images , 1996 .

[13]  P L Weissberg Atherogenesis: current understanding of the causes of atheroma. , 2000, Heart.

[14]  Bob S. Hu,et al.  High‐resolution three‐dimensional in vivo imaging of atherosclerotic plaque , 1999, Magnetic resonance in medicine.

[15]  V. Fuster,et al.  The Vulnerable Atherosclerotic Plaque: Understanding, Identification, and Modification , 1999, Cardiovascular Drugs and Therapy.

[16]  Milan Sonka,et al.  Object localization and border detection criteria design in edge-based image segmentation: automated learning from examples , 2000, IEEE Transactions on Medical Imaging.

[17]  Milan Sonka,et al.  Assessment of plaque stability by means of high-resolution MRI and finite element analyses of local stresses and strains , 2002, Proceedings IEEE International Symposium on Biomedical Imaging.

[18]  V. Fuster,et al.  Magnetic resonance images lipid, fibrous, calcified, hemorrhagic, and thrombotic components of human atherosclerosis in vivo. , 1996, Circulation.

[19]  V. Fuster,et al.  In vivo magnetic resonance evaluation of atherosclerotic plaques in the human thoracic aorta: a comparison with transesophageal echocardiography. , 2000, Circulation.

[20]  P W Serruys,et al.  Clinical and angiographic outcome of elective stent implantation in small coronary vessels: an analysis of the BENESTENT trial. , 1996, Seminars in interventional cardiology : SIIC.

[21]  Milan Sonka,et al.  Geometrically correct 3-D reconstruction of intravascular ultrasound images by fusion with biplane angiography-methods and validation , 1999, IEEE Transactions on Medical Imaging.

[22]  Chun Yuan,et al.  Identification of Fibrous Cap Rupture With Magnetic Resonance Imaging Is Highly Associated With Recent Transient Ischemic Attack or Stroke , 2002, Circulation.

[23]  G. V. R. Born,et al.  INFLUENCE OF PLAQUE CONFIGURATION AND STRESS DISTRIBUTION ON FISSURING OF CORONARY ATHEROSCLEROTIC PLAQUES , 1989, The Lancet.

[24]  R D Kamm,et al.  Effects of fibrous cap thickness on peak circumferential stress in model atherosclerotic vessels. , 1992, Circulation research.

[25]  Gerhard A. Holzapfel,et al.  Nonlinear Solid Mechanics: A Continuum Approach for Engineering Science , 2000 .

[26]  F Alfonso,et al.  Long-term angiographic results of stenting in chronic total occlusions: influence of stent design and vessel size. , 1999, American heart journal.

[27]  T K Foo,et al.  Techniques for high‐resolution MR imaging of atherosclerotic plaque , 1994, Journal of magnetic resonance imaging : JMRI.

[28]  M. Davies,et al.  Risk of thrombosis in human atherosclerotic plaques: role of extracellular lipid, macrophage, and smooth muscle cell content. , 1993, British heart journal.