First in situ determination of the ground thermal conductivity for boreholeheat exchanger applications in Saudi Arabia

The paper deals with the in situ experimental determination of the thermal properties of the underground soil for use in the design of borehole heat exchangers (BHE). The approach is based on recording the unsteady thermal response of a BHE that has been installed for the first time in Saudi Arabia. In this approach, the temperature of the circulating fluid has been recorded at the inlet and outlet sections of the BHE with time following the start of its operation. Severe fluctuations in these temperatures occur at small times (up to 8h) due to the transient effects inside the borehole and must be excluded. A method has been developed for estimating the time period characterized by these severe fluctuations. The recorded thermal responses together with the line source theory are used to determine the thermal conductivity, thermal diffusivity and the steady-state equivalent thermal resistance of the underground soil.

[1]  Lingen Chen,et al.  Ground heat exchanger temperature distribution analysis and experimental verification , 2002 .

[2]  Johan Claesson,et al.  Conductive heat extraction to a deep borehole: Thermal analyses and dimensioning rules , 1988 .

[3]  Naser A. Al-Shayea,et al.  Inherent heterogeneity of sediments in Dhahran, Saudi Arabia : a case study , 2000 .

[4]  K. Lim,et al.  An experimental study on the thermal performance of ground heat exchanger , 2007 .

[5]  S. Gehlin,et al.  TED - a mobile equipment for thermal response test : testing and evaluation , 1996 .

[6]  Frank P. Incropera,et al.  Fundamentals of Heat and Mass Transfer , 1981 .

[7]  J. Beck,et al.  Field Test of a New Method for Determining Soil Formation Thermal Conductivity and Borehole Resistance , 2000 .

[8]  P. Mogensen Fluid to duct wall heat transfer in duct system heat storages , 1983 .

[9]  Z. Fang,et al.  Heat transfer analysis of boreholes in vertical ground heat exchangers , 2003 .

[10]  J. P. Holman,et al.  Experimental methods for engineers , 1971 .

[11]  Esmail M. A. Mokheimer,et al.  Energy, exergy and uncertainty analyses of the thermal response test for a ground heat exchanger , 2009 .

[12]  Zhihao Chen,et al.  Simulation and experiment on the thermal performance of U-vertical ground coupled heat exchanger , 2006 .

[13]  J. Claesson,et al.  SIMULATION MODEL FOR THERMALLY INTERACTING HEAT EXTRACTION BOREHOLES , 1988 .

[14]  J. E. Bose,et al.  Design/data manual for closed-loop ground-coupled heat pump systems , 1985 .

[15]  J. D. Deerman Simulation of Vertical U-tube Ground-coupled Heat Pump Systems using the Cylindrical Heat Source Solution , 1991 .

[16]  Halime Paksoy,et al.  Aquifer thermal storage (ATES) for air-conditioning of a supermarket in Turkey , 2004 .