Fabrication and Characterization of Ultrathin-ring Electrodes for Pseudo-steady-state Amperometric Detection

The fabrication of ultrathin-ring electrodes with a diameter of 2 mm and a thickness of 100 nm is established. The ultrathin-ring electrodes provide a large density of pseudo-steady-state currents, and realize pseudo-steady-state amperometry under quiescent conditions without a Faraday cage. Under the limiting current conditions, the current response at the ultrathin-ring electrode can be well explained by the theory of the microband electrode response. Cyclic voltammograms at the ultrathin-ring electrode show sigmoidal characteristics with some hysteresis. Numerical simulation reveals that the hysteresis can be ascribed to the time-dependence of pseudo-steady-state current. The performance of amperometry with the ultrathin-ring electrode has been verified in its application to redox enzyme kinetic measurements.

[1]  Hoeil Chung,et al.  Spirally oriented Au microelectrode array sensor for detection of Hg (II). , 2012, Talanta.

[2]  O. Shirai,et al.  Bioelectrocatalytic endpoint assays based on steady-state diffusion current at microelectrode array , 2010 .

[3]  Trevor J. Davies,et al.  The cyclic and linear sweep voltammetry of regular and random arrays of microdisc electrodes: Theory , 2005 .

[4]  B. Conway,et al.  Evaluation and origins of the difference between double-layer capacitance behaviour at Au-metal and oxidized Au surfaces , 2004 .

[5]  K. Kano,et al.  Theory of steady-state catalytic current of mediated bioelectrocatalysis , 2002 .

[6]  H. Hill,et al.  A voltammetric study of direct electron transfer to cytochrome c using a very large assembly of carbon microelectrodes. , 2001, Lab on a chip.

[7]  Robert J. Forster,et al.  Microelectrodes: new dimensions in electrochemistry , 1994 .

[8]  A. Bard,et al.  Simple analysis of quasi-reversible steady-state voltammograms , 1992 .

[9]  K. B. Oldham,et al.  Steady-State Voltammetry , 1989 .

[10]  Alan M. Bond,et al.  An evaluation of ultrathin ring and band microelectrodes as amperometric sensors in electrochemical flow cells , 1989 .

[11]  B. Scharifker Diffusion to ensembles of microelectrodes , 1988 .

[12]  H. Gunasingham,et al.  Electrochemical detection for liquid chromatography using the wall-jet cell/ultramicroelectrode detector , 1987 .

[13]  Davis K. Cope,et al.  Chronoamperometric current at hemicylinder and band microelectrodes: Theory and experiment , 1987 .

[14]  M. Fleischmann,et al.  The behavior of microring electrodes , 1985 .

[15]  D. Macfarlane,et al.  Thin-ring ultra-microelectrodes , 1985 .

[16]  A. Turner,et al.  Ferrocene-mediated enzyme electrode for amperometric determination of glucose. , 1984, Analytical chemistry.

[17]  Koichi Aoki,et al.  Diffusion-controlled current at the stationary finite disk electrode: Theory , 1981 .

[18]  Yukio Saito,et al.  A Theoretical Study on the Diffusion Current at the Stationary Electrodes of Circular and Narrow Band Types , 1968 .