Acute and long‐term outcomes after polytetrafluoroethylene or pericardium covered stenting for grade 3 coronary artery perforations: Insights from G3‐CAP registry

Covered stent (CS) implantation is considered a useful device in the setting of Grade III Coronary Perforation (G3CP), one of the most harmful PCI complication. However, data regarding efficacy of this device and clinical outcomes are still limited.

[1]  S. Garcia,et al.  Incidence, Treatment, and Outcomes of Coronary Perforation During Chronic Total Occlusion Percutaneous Coronary Intervention. , 2017, The American journal of cardiology.

[2]  A. Mathur,et al.  Prevalence and outcomes of coronary artery perforation during percutaneous coronary intervention. , 2017, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[3]  R. Garbo,et al.  The Balloon‐Microcatheter technique for treatment of coronary artery perforations , 2017, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[4]  Chiung‐Jen Wu,et al.  Clinical Outcomes Following Covered Stent for the Treatment of Coronary Artery Perforation. , 2016, Journal of interventional cardiology.

[5]  C. Di Mario,et al.  Indications and immediate and long‐term results of a novel pericardium covered stent graft: Consecutive 5 year single center experience , 2016, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[6]  K. Takagi,et al.  Short-Term and Long-Term Outcomes After Polytetrafluoroethylene-Covered Stent Implantation for the Treatment of Coronary Perforation. , 2015, The American journal of cardiology.

[7]  K. Garratt,et al.  Guidewire-induced coronary artery perforation and tamponade during PCI: in-hospital outcomes and impact on long-term survival. , 2014, The Journal of invasive cardiology.

[8]  Shaosong Zhang,et al.  Optical coherence tomographic observations of polytetrafluoroethylene-covered sirolimus-eluting coronary arterial stent. , 2013, The American journal of cardiology.

[9]  A. Shimony,et al.  Coronary artery perforation during percutaneous coronary intervention: a systematic review and meta-analysis. , 2011, The Canadian journal of cardiology.

[10]  M. Takano,et al.  Delayed healing of a coronary stent graft. , 2011, JACC. Cardiovascular interventions.

[11]  G. Stone,et al.  5-year follow-up of polytetrafluoroethylene-covered stents compared with bare-metal stents in aortocoronary saphenous vein grafts the randomized BARRICADE (barrier approach to restenosis: restrict intima to curtail adverse events) trial. , 2011, JACC. Cardiovascular interventions.

[12]  A. Colombo,et al.  Incidence, predictors, management, immediate and long-term outcomes following grade III coronary perforation. , 2011, JACC. Cardiovascular interventions.

[13]  J. Wykrzykowska,et al.  “Over‐and‐under” pericardial covered stent with paclitaxel balloon in a saphenous vein graft , 2010, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[14]  A. Colombo,et al.  The pericardium covered stent (PCS). , 2009, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[15]  P. Serruys,et al.  Clinical End Points in Coronary Stent Trials: A Case for Standardized Definitions , 2007, Circulation.

[16]  K. Kent,et al.  Management and outcomes of coronary artery perforation during percutaneous coronary intervention. , 2006, The American journal of cardiology.

[17]  G. Stone,et al.  Treatment of coronary artery perforations complicating percutaneous coronary intervention with a polytetrafluoroethylene-covered stent graft. , 2006, The American journal of cardiology.

[18]  Michail I. Papafaklis,et al.  Clinical and angiographic follow-up after overlapping implantation of polytetrafluoroethylene covered stents with drug eluting stents. , 2006, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[19]  C. Lotan,et al.  Use of polytetrafluoroethylene‐covered stent for treatment of coronary artery aneurysm , 2005, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[20]  H. Ly,et al.  Angiographic and clinical outcomes of polytetrafluoroethylene-covered stent use in significant coronary perforations. , 2005, The American journal of cardiology.

[21]  M. Jeong,et al.  Combined membrane covered and uncovered stents for coronary arteriovenous fistula associated with atherosclerotic plaque in a patient with acute myocardial infarction , 2004, Heart.

[22]  C. Di Mario,et al.  Randomized Evaluation of Polytetrafluoroethylene‐Covered Stent in Saphenous Vein Grafts: The Randomized Evaluation of polytetrafluoroethylene COVERed stent in Saphenous vein grafts (RECOVERS) Trial , 2003, Circulation.

[23]  J. Abbott,et al.  Treatment of a Left Internal Mammary Artery to Pulmonary Artery Fistula with Polytetrafluoroethylene Covered Stents: A Case Report and Review of the Literature , 2003, CardioVascular and Interventional Radiology.

[24]  M. Leon,et al.  Results of the Jostent coronary stent graft implantation in various clinical settings: Procedural and follow‐up results , 2002, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[25]  D. Kereiakes,et al.  Coronary perforation during percutaneous coronary intervention in the era of abciximab platelet glycoprotein IIb/IIIa blockade: An algorithm for percutaneous management , 2001, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[26]  C. Di Mario,et al.  Emergency Polytetrafluoroethylene-Covered Stent Implantation to Treat Coronary Ruptures , 2000, Circulation.

[27]  S. Woodfield,et al.  Obliteration of a Coronary Artery Aneurysm With a PTFE‐Covered Stent: Endoluminal Graft for Coronary Disease Revisited , 1999, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[28]  A. Roguin,et al.  Percutaneous closure of a coronary aneurysm with a vein-coated stent. , 1998, Catheterization and cardiovascular diagnosis.

[29]  S. Ellis,et al.  Increased Coronary Perforation in the New Device Era: Incidence, Classification, Management, and Outcome , 1994, Circulation.

[30]  S. Goldberg,et al.  Improved stability and visualization during coronary artery angioplasty using a double catheter technique. , 1986, Catheterization and cardiovascular diagnosis.