Development of a novel radiation imaging detector system for in vivo gene imaging in small animal studies

Many studies in molecular biology deal with following the expression and regulation of a gene at different stages of an organism's development or under different physiological conditions. Presently in situ hybridization and immunochemical assays are available to follow the gene expression at a single moment in time for one organism. One must sacrifice the organism to make a measurement, essentially taking a snap shot of the state of expression of the gene of interest. We have made progress on a new type of gene imaging technology which takes advantage of the emission properties of the radioisotope iodine 125 (/sup 125/I) as the probe and utilizes crystal scintillators and a position sensitive photomultiplier tube. Iodine 125 decays via electron capture emitting a 35 keV gamma-ray with the prompt emission of several 27-32 keV K/spl alpha/ and K/spl beta/ shell X-rays. Because of this a coincidence condition can be set to detect the /sup 125/I decays thus reducing background radiation contribution to the image. Mouse imaging studies of iodine uptake by the thyroid and melatonin receptor binding have been done with this detector system using low doses of /sup 125/I.

[1]  R G Blasberg,et al.  Noninvasive imaging of herpes virus thymidine kinase gene transfer and expression: a potential method for monitoring clinical gene therapy. , 1996, Cancer research.

[2]  C. Pedersen,et al.  Antisense oligodeoxynucleotide complementary to oxytocin mRNA blocks lactation in rats. , 2009, Experimental and clinical endocrinology & diabetes : official journal, German Society of Endocrinology [and] German Diabetes Association.

[3]  R. Blasberg,et al.  Imaging the expression of transfected genes in vivo. , 1995, Cancer research.

[4]  Y. Yonekura,et al.  Ultra-high resolution SPECT system using four pinhole collimators for small animal studies. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  K. Peters,et al.  Green fluorescent fusion proteins: powerful tools for monitoring protein expression in live zebrafish embryos. , 1995, Developmental biology.

[6]  Roberto Pani,et al.  Scintillation properties of YAP:Ce , 1995 .

[7]  Francesco Scopinaro,et al.  Toward a nuclear medicine with sub-millimiter spatial resolution , 1995 .

[8]  H. Sakahara,et al.  Improved targeting of radiolabeled streptavidin in tumors pretargeted with biotinylated monoclonal antibodies through an avidin chase. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  F. Mangili,et al.  Radioimmunoguided surgery using iodine-125-labeled biotinylated monoclonal antibodies and cold avidin. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  G. Sfakianakis,et al.  Noninvasive imaging of c-myc oncogene messenger RNA with indium-111-antisense probes in a mammary tumor-bearing mouse model. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  R. Jaszczak,et al.  Pinhole collimation for ultra-high-resolution, small-field-of-view SPECT. , 1994, Physics in medicine and biology.

[12]  P. Morgan,et al.  Melatonin receptors: Localization, molecular pharmacology and physiological significance , 1994, Neurochemistry International.

[13]  C. Chen,et al.  A Single-tube Miniature Gamma Camera , 1993, 1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference.

[14]  D. Pfaff,et al.  Enduring consequences of neonatal treatment with antisense oligodeoxynucleotides to estrogen receptor messenger ribonucleic acid on sexual differentiation of rat brain. , 1993, Endocrinology.

[15]  John O. Prior,et al.  New approaches in medical imaging using plastic scintillating detectors , 1993 .

[16]  R. Ott,et al.  c-erbB2 protein overexpression in breast cancer as a target for PET using iodine-124-labeled monoclonal antibodies. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[17]  S. Adelstein,et al.  Radiotoxicity of 125I in mammalian cells. , 1987, Radiation research.

[18]  A. Longoni,et al.  Optimum geometry for strip cathodes or grids in MWPC for avalanche localization along the anode wires , 1979 .

[19]  Fabio Sauli,et al.  High-accuracy, bidimensional read-out of proportional chambers with short resolution times , 1977 .

[20]  D. Horrocks,et al.  Theoretical considerations for standardization of 125I by the coincidence method , 1975 .

[21]  E. L. Keller,et al.  Optimum dimensions of parallel-hole, multi-aperture collimators for gamma-ray cameras. , 1968, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[22]  H. Anger,et al.  CHAPTER 19 – RADIOISOTOPE CAMERAS , 1967 .