Abstract This work performs a comprehensive characterization of the relation between energy use and ventilation rates in both residential and services buildings in the diversity of European climates. Through detailed building simulation, a sensitivity analysis was performed considering four building types (detached house, apartment, office and school), three climates/locations (Helsinki, Paris and Lisbon), three heating and cooling setpoints settings, four air-flow control strategies, usage of heat recovery coupled with four different building airtightness conditions, and three ranges of humidity control. The impacts of changing ventilation rate (ICV) were determined for each case as being the slope of the energy needs as function of the ventilation rate, in the range of 0–50 m3/(h person). The energy results, assessed through dynamic building simulation, show that changing ventilation by 1 m3/(h person) with current practice systems has an impact in total HVAC-related final energy demand between 0.3 and 0.6 kWh/(m2 year) depending on building type and location. However, with advanced systems the ICV values could become close to 0.1 [kWh/(m2 year)]/[m3/(h person)] in most cases analyzed. These results can be used to assess the energy impacts of IAQ polices, including hypothetical trade-offs between health and energy or different degrees of use of the precautionary principle.

[1]  K. Lück Energy efficient building services for tempering performance-oriented interior spaces – A literature review , 2012 .

[2]  M Orme,et al.  Energy and ventilation , 1998 .

[3]  Edward Henry Mathews,et al.  Developing cost efficient control strategies to ensure optimal energy use and sufficient indoor comfort , 2000 .

[4]  Maria Kolokotroni,et al.  Cooling-energy reduction in air-conditioned offices by using night ventilation , 1999 .

[5]  Ambrose Dodoo,et al.  Primary energy implications of ventilation heat recovery in residential buildings , 2011 .

[6]  Luis Pérez-Lombard,et al.  The map of energy flow in HVAC systems , 2011 .

[7]  Max H. Sherman,et al.  Residential ventilation and energy characteristics , 1997 .

[8]  Claude-Alain Roulet,et al.  Real heat recovery with air handling units , 2001 .

[9]  Max H. Sherman,et al.  Meeting Residential Ventilation Standards Through Dynamic Control of Ventilation Systems , 2011 .

[10]  J. Sundell,et al.  On the history of indoor air quality and health. , 2004, Indoor air.

[11]  Max H. Sherman,et al.  Optimization of Occupancy Based Demand Controlled Ventilation in Residences , 2011 .

[12]  Francis Allard,et al.  Night ventilation for building cooling in summer , 1997 .

[13]  Mohammad S. Al-Homoud,et al.  Effect of ventilation strategies on air contaminant concentrations and energy consumption in buildings , 2001 .

[14]  Luis Pérez-Lombard,et al.  A review on buildings energy consumption information , 2008 .

[15]  K. F. Fong,et al.  Comparison of annual energy performances with different ventilation methods for temperature and humi , 2011 .

[16]  Lars J Nilsson,et al.  Air-handling energy efficiency and design practices , 1995 .

[17]  M. Orme Estimates of the energy impact of ventilation and associated financial expenditures , 2001 .

[18]  Andrew K. Persily,et al.  Impacts of airtightening retrofits on ventilation rates and energy consumption in a manufactured hom , 2010 .