Targeting Accuracy under Model-to-Subject Misalignments in Model-Guided Cardiac Surgery

In image-guided interventions, anatomical models of organs are often generated from pre-operative images and further employed in planning and guiding therapeutic procedures. However, the accuracy of these models, along with their registration to the subject are crucial for successful therapy delivery. These factors are amplified when manipulating soft tissue undergoing large deformations, such as the heart. When used in guiding beating-heart procedures, pre-operative models may not be sufficient for guidance and they are often complemented with real-time, intra-operative cardiac imaging. Here we demonstrate via in vitro endocardial "therapy" that ultrasound-enhanced model-guided navigation provides sufficient guidance to preserve a clinically-desired targeting accuracy of under 3 mm independently of the model-to-subject misregistrations. These results emphasize the direct benefit of integrating real-time imaging within intra-operative visualization environments considering that model-to-subject misalignments are often encountered clinically.

[1]  F. Sauer Image Registration: Enabling Technology for Image Guided Surgery and Therapy , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[2]  Douglas L. Jones,et al.  Inside the beating heart: an in vivo feasibility study on fusing pre- and intra-operative imaging for minimally invasive therapy , 2009, International Journal of Computer Assisted Radiology and Surgery.

[3]  YingLiang Ma,et al.  Echocardiography to magnetic resonance image registration for use in image-guide electrophysiology procedures , 2009, Medical Imaging.

[4]  Terry M. Peters,et al.  Object identification accuracy under ultrasound enhanced virtual reality for minimally invasive cardiac surgery , 2008, SPIE Medical Imaging.

[5]  K. Cleary,et al.  Image-guided interventions : technology and applications , 2008 .

[6]  Computer-Assisted Intervention,et al.  Medical Image Computing and Computer-Assisted Intervention – MICCAI’99 , 1999, Lecture Notes in Computer Science.

[7]  Terry M. Peters,et al.  Ultrasound Probe Tracking for Real-Time Ultrasound/MRI Overlay and Visualization of Brain Shift , 1999, MICCAI.

[8]  R A Robb,et al.  An integrated system for real-time image guided cardiac catheter ablation. , 2006, Studies in health technology and informatics.

[9]  Reza Ardehali,et al.  Percutaneous valve replacement: current state and future prospects. , 2004, The Annals of thoracic surgery.

[10]  Andrew D. Wiles,et al.  Virtual reality-enhanced ultrasound guidance: A novel technique for intracardiac interventions , 2008, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[11]  Terry M. Peters,et al.  In vitro cardiac catheter navigation via augmented reality surgical guidance , 2009, Medical Imaging.

[12]  Thomas A Vassiliades,et al.  The clinical development of percutaneous heart valve technology: a position statement of the Society of Thoracic Surgeons (STS), the American Association for Thoracic Surgery (AATS), and the Society of Cardiovascular Angiography and Intervention (SCAI). , 2005, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[13]  D. Doty,et al.  Cardiac Valve Operations Using a Partial Sternotomy (Lower Half) Technique , 2000, Journal of cardiac surgery.

[14]  Thomas A Vassiliades,et al.  The clinical development of percutaneous heart valve technology. , 2005, The Journal of thoracic and cardiovascular surgery.

[15]  K. Cleary,et al.  Image Guided Interventions. , 2020, Biomedizinische Technik. Biomedical engineering.