Hysteresis Control for Shunt Active Power Filter under Unbalanced Three-Phase Load Conditions

This paper focuses on a four-wire shunt active power filter (APF) control scheme proposed to improve the performance of the APF. This filter is used to compensate harmonic distortion in three-phase four-wire systems. Several harmonic suppression techniques have been widely proposed and applied to minimize harmonic effects. The proposed control scheme can compensate harmonics and reactive power of the nonlinear loads simultaneously. This approach is compared to the conventional shunt APF reference compensation strategy. The developed algorithm is validated by simulation tests using MATLAB Simulink. The obtained results have demonstrated the effectiveness of the proposed scheme and confirmed the theoretical developments for balanced and unbalanced nonlinear loads.

[1]  Rahmat Allah Hooshmand,et al.  A new combined method in active filter design for power quality improvement in power systems. , 2011, ISA transactions.

[2]  Aaas News,et al.  Book Reviews , 1893, Buffalo Medical and Surgical Journal.

[3]  Alina G. Stan,et al.  A Matlab-Simulink Approach To Shunt Active Power Filters , 2011, ECMS.

[4]  Wang Huaisheng,et al.  A Novel Double Hysteresis Current Control Method For Active Power Filter , 2012 .

[5]  Salah Saad,et al.  A comparative study of harmonic currents extraction by simulation and implementation , 2013 .

[6]  Besir Dandil,et al.  Three Level Inverter Based Shunt Active Power Filter Using Multi-Level Hysteresis Band Current Controller , 2012 .

[7]  Hirofumi Akagi,et al.  Instantaneous power theory and applications to power conditioning , 2007 .

[8]  Tarjei Midtsund Control of Power Electronic Converters in Distributed Power Generation Systems: Evaluation of Current Control Structures for Voltage Source Converters operating under Weak Grid Conditions , 2010 .

[9]  Robert Altenloh From a Novel , 1953 .

[10]  E.R. Cadaval,et al.  Comparison of Control Strategies for Shunt Active Power Filters in Three-Phase Four-Wire Systems , 2007, IEEE Transactions on Power Electronics.

[11]  S. Arumugam,et al.  A Comparative Performance Analysis of Four Control Algorithms for a Three Phase Shunt Active Power Filter , 2010 .

[12]  V. Agarwal,et al.  A novel, DSP based algorithm for optimizing the harmonics and reactive power under non-sinusoidal supply voltage conditions , 2005, IEEE Transactions on Power Delivery.

[13]  W. Marsden I and J , 2012 .

[14]  Patricia Liliana Arnera,et al.  Hybrid Power Filter to Enhance Power Quality in a Medium-Voltage Distribution Network , 2009, IEEE Transactions on Industrial Electronics.

[15]  P Karuppanan,et al.  Three level hysteresis current controller based active power filter for harmonic compensation , 2011, 2011 International Conference on Emerging Trends in Electrical and Computer Technology.

[16]  Júlio S. Martins,et al.  Active filters with control based on the p-q theory , 2000 .

[17]  Mehmet Uçar,et al.  Control of a 3-phase 4-leg active power filter under non-ideal mains voltage condition , 2008 .

[18]  R. Belaidia,et al.  Fuzzy Logic Controller Based Three-Phase Shunt Active Power Filter for Compensating Harmonics and Reactive Power under Unbalanced Mains Voltages , 2012 .

[19]  Ankita Singh,et al.  Performance Investigation of Active Power Line Conditioner using Simulink , 2012 .