Simulation of Self Expanding Transcatheter Aortic Valve in a Realistic Aortic Root: Implications of Deployment Geometry on Leaflet Deformation

Self expanding Transcatheter Aortic Valve Replacements (TAVR) can conform to the geometry of the aortic annulus and the calcified leaflet complex, which may result in leaflet distortion and altered leaflet kinematics, but such changes have not yet been characterized. In this study we developed a computational model to investigate the deployment of a self expanding TAVR in a realistic aortic root model derived from multi-slice computed tomography (MSCT) images. We simulated TAVR crimping/deployment in realistic and idealized aortic root models, followed by diastolic loading of the TAVR leaflets in its final deployed configuration. The TAVR deployed in a realistic aortic root had increased peak loading in the commissural region of the leaflets compared to TAVRs under idealized circular deployment conditions (2.97 vs. 1.52 MPa). Furthermore, orientation of the TAVR in the asymmetric aortic annulus such that the commissures of the TAVR are aligned with the native valve commissures minimized the effect of TAVR stent distortion on peak stresses in the TAVR leaflets (2.97 vs. 2.35 MPa). We propose that preoperative planning of the orientation of the TAVR in the aortic root annulus might minimize the impact of potential stent distortion on leaflet function and may in turn increase long term leaflet durability.

[1]  A Rachev,et al.  Residual strains in conduit arteries. , 2003, Journal of biomechanics.

[2]  Ashraf Hamdan,et al.  Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy. , 2012, Journal of the American College of Cardiology.

[3]  Michael S. Sacks,et al.  Orthotropic Mechanical Properties of Chemically Treated Bovine Pericardium , 1998, Annals of Biomedical Engineering.

[4]  Neelakantan Saikrishnan,et al.  Hemodynamics of the Boston Scientific Lotus™ Valve: An In Vitro Study , 2013 .

[5]  Philippe Ravaud,et al.  A prospective survey of patients with valvular heart disease in Europe: The Euro Heart Survey on Valvular Heart Disease. , 2003, European heart journal.

[6]  E A Trowbridge,et al.  The extension rate independence of the hysteresis in glutaraldehyde-fixed bovine pericardium. , 1987, Biomaterials.

[7]  F Auricchio,et al.  Simulation of transcatheter aortic valve implantation: a patient-specific finite element approach , 2014, Computer methods in biomechanics and biomedical engineering.

[8]  Ferdinando Auricchio,et al.  Shape-memory alloys: macromodelling and numerical simulations of the superelastic behavior , 1997 .

[9]  R. P. Cochran,et al.  Dynamic Finite Element Implementation of Nonlinear, Anisotropic Hyperelastic Biological Membranes , 2003, Computer methods in biomechanics and biomedical engineering.

[10]  Wei Sun,et al.  Simulated elliptical bioprosthetic valve deformation: implications for asymmetric transcatheter valve deployment. , 2010, Journal of biomechanics.

[11]  Lee Jm,et al.  The bovine pericardial xenograft: I. Effect of fixation in aldehydes without constraint on the tensile viscoelastic properties of bovine pericardium , 1989 .

[12]  D R Boughner,et al.  The bovine pericardial xenograft: I. Effect of fixation in aldehydes without constraint on the tensile viscoelastic properties of bovine pericardium. , 1989, Journal of biomedical materials research.

[13]  Yen Chang,et al.  Crosslinking characteristics and mechanical properties of a bovine pericardium fixed with a naturally occurring crosslinking agent. , 1999, Journal of biomedical materials research.

[14]  S Tzamtzis,et al.  Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI). , 2013, Medical engineering & physics.

[15]  Erich Wintermantel,et al.  Finite Element Investigation of Stentless Pericardial Aortic Valves: Relevance of Leaflet Geometry , 2010, Annals of Biomedical Engineering.

[16]  J. Gorman,et al.  Effect of Geometry on the Leaflet Stresses in Simulated Models of Congenital Bicuspid Aortic Valves , 2011, Cardiovascular engineering and technology.

[17]  Wei Sun,et al.  Patient-specific modeling of biomechanical interaction in transcatheter aortic valve deployment. , 2012, Journal of biomechanics.

[18]  Caitríona Lally,et al.  Simulation of a balloon expandable stent in a realistic coronary artery-Determination of the optimum modelling strategy. , 2010, Journal of biomechanics.

[19]  Ulrich Steinseifer,et al.  In vitro assessment of the influence of aortic annulus ovality on the hydrodynamic performance of self-expanding transcatheter heart valve prostheses. , 2014, Journal of biomechanics.

[20]  R. Guyton,et al.  An Engineering Review of Transcatheter Aortic Valve Technologies , 2010 .

[21]  Silvia Schievano,et al.  Patient-specific simulations of transcatheter aortic valve stent implantation , 2012, Medical & Biological Engineering & Computing.

[22]  Josep Rodés-Cabau,et al.  Transcatheter aortic valve implantation: current and future approaches , 2012, Nature Reviews Cardiology.

[23]  Liang Ge,et al.  Engineering perspective on transcatheter aortic valve implantation , 2013 .

[24]  Laoise M. McNamara,et al.  An In Vitro Evaluation of the Impact of Eccentric Deployment on Transcatheter Aortic Valve Hemodynamics , 2014, Annals of Biomedical Engineering.

[25]  Miguel A. Cavero,et al.  Implicaciones pronósticas de la morfología asimétrica en la implantación de prótesis aórticas transcatéter: A propósito de un caso , 2012 .

[26]  C Scheffer,et al.  Application of finite element analysis to the design of tissue leaflets for a percutaneous aortic valve. , 2009, Journal of the mechanical behavior of biomedical materials.

[27]  David E. Schmidt,et al.  On the biomechanics of heart valve function. , 2009, Journal of biomechanics.

[28]  Mathias Langer,et al.  Conformational pulsatile changes of the aortic annulus: impact on prosthesis sizing by computed tomography for transcatheter aortic valve replacement. , 2012, JACC. Cardiovascular interventions.

[29]  Ferdinando Auricchio,et al.  Shape-memory alloys: modelling and numerical simulations of the finite-strain superelastic behavior , 1997 .

[30]  F Auricchio,et al.  Patient-specific simulation of a stentless aortic valve implant: the impact of fibres on leaflet performance , 2014, Computer methods in biomechanics and biomedical engineering.

[31]  Wei Sun,et al.  Simulation of long-term fatigue damage in bioprosthetic heart valves: effects of leaflet and stent elastic properties , 2014, Biomechanics and modeling in mechanobiology.

[32]  J. Goicolea,et al.  Prognostic implications of asymmetric morphology in transcatheter aortic valve implantation: a case report. , 2012, Revista espanola de cardiologia.

[33]  Gábor Székely,et al.  Simulation of transcatheter aortic valve implantation under consideration of leaflet calcification , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[34]  Kewei Li,et al.  Simulated Thin Pericardial Bioprosthetic Valve Leaflet Deformation Under Static Pressure-Only Loading Conditions: Implications for Percutaneous Valves , 2010, Annals of Biomedical Engineering.

[35]  C. Kleinstreuera,et al.  Computational mechanics of Nitinol stent grafts , 2008 .

[36]  Nico Mollet,et al.  Geometry and degree of apposition of the CoreValve ReValving system with multislice computed tomography after implantation in patients with aortic stenosis. , 2009, Journal of the American College of Cardiology.

[37]  Alberto Redaelli,et al.  Aortic root performance after valve sparing procedure: a comparative finite element analysis. , 2009, Medical engineering & physics.

[38]  Ghassan Sleilaty,et al.  Is it reasonable to treat all calcified stenotic aortic valves with a valved stent? Results from a human anatomic study in adults. , 2008, Journal of the American College of Cardiology.