URETERAL INJURY AFTER LAPAROSCOPIC TUBAL STERILIZATION BY BIPOLAR ELECTROCOAGULATION

In bipolar electrocoagulation of the fallopian tubes, the electric current is between the tips of the forceps, which are visualized. Therefore, unnoticed burn injuries are uncommon. We describe a case of ureteral stenosis due to inadvertent burn injury, which was successfully managed conservatively.