An Implantable CMOS Image Sensor With Self-Reset Pixels for Functional Brain Imaging

In this paper, we propose and demonstrate an implantable CMOS image sensor with self-resetting pixels. The self-resetting function is implemented using a four-transistor Schmitt trigger inverter. The pixel has no counter for the number of self-resets, because the application does not require radiometric (linear) response. The pixel is fabricated using the 0.35-μm 2-poly 4-metal standard CMOS technology, which results in the pixel size of 15 μm×15 μm and a fill factor of 31%. The effective peak signal-to-noise ratio is >59 dB. An image sensor prototype comprising a 60 × 134 pixel array is designed, and an implantable device is fabricated. As an example imaging experiment, we demonstrate blood-flow imaging of a rat-brain surface using the sensor. Intensity-change images are successfully obtained from the self-resetting pixel outputs with the image processing.

[1]  Yoshihiro Fujita,et al.  A digital pixel image sensor for real-time readout , 2000 .

[2]  Keiichiro Kagawa,et al.  Proposal of Application of Pulsed Vision Chip for Retinal Prosthesis. , 2002 .

[3]  Amine Bermak,et al.  A vision sensor with on-pixel ADC and in-built light adaptation mechanism , 2002 .

[4]  Keiichiro Kagawa,et al.  Pixel design of pulsed CMOS image sensor for retinal prosthesis with digital photosensitivity control , 2003 .

[5]  A. Mehta,et al.  In vivo mammalian brain imaging using one- and two-photon fluorescence microendoscopy. , 2004, Journal of neurophysiology.

[6]  Amiram Grinvald,et al.  VSDI: a new era in functional imaging of cortical dynamics , 2004, Nature Reviews Neuroscience.

[7]  Junichi Nakamura,et al.  Image Sensors and Signal Processing for Digital Still Cameras , 2005 .

[8]  A. Grinvald,et al.  Compartment-Resolved Imaging of Activity-Dependent Dynamics of Cortical Blood Volume and Oximetry , 2005, The Journal of Neuroscience.

[9]  C. Petersen,et al.  Visualizing the Cortical Representation of Whisker Touch: Voltage-Sensitive Dye Imaging in Freely Moving Mice , 2006, Neuron.

[10]  Masahiro Nunoshita,et al.  On-chip biofluorescence imaging inside a brain tissue phantom using a CMOS image sensor for in vivo brain imaging verification , 2006 .

[11]  Xiuling Wang,et al.  A High Dynamic Range CMOS Image Sensor With Inpixel Light-to-Frequency Conversion , 2006, IEEE Transactions on Electron Devices.

[12]  Elizabeth M C Hillman,et al.  Optical brain imaging in vivo: techniques and applications from animal to man. , 2007, Journal of biomedical optics.

[13]  D. Park,et al.  A Wide Dynamic-Range CMOS Image Sensor Using Self-Reset Technique , 2007, IEEE Electron Device Letters.

[14]  Jun Ohta,et al.  Smart CMOS Image Sensors and Applications , 2007 .

[15]  Jun Ohta,et al.  One-chip sensing device (biomedical photonic LSI) enabled to assess hippocampal steep and gradual up-regulated proteolytic activities , 2008, Journal of Neuroscience Methods.

[16]  Shu Chien,et al.  Fluorescence proteins, live-cell imaging, and mechanobiology: seeing is believing. , 2008, Annual review of biomedical engineering.

[17]  David S. Greenberg,et al.  Visually evoked activity in cortical cells imaged in freely moving animals , 2009, Proceedings of the National Academy of Sciences.

[18]  Bing Liu,et al.  An Activity-Triggered 95.3 dB DR $-$75.6 dB THD CMOS Imaging Sensor With Digital Calibration , 2009, IEEE Journal of Solid-State Circuits.

[19]  Sungyong Jung,et al.  A 105.6dB DR and 65dB peak SNR self-reset CMOS image sensor using a Schmitt trigger circuit , 2011, 2011 IEEE 54th International Midwest Symposium on Circuits and Systems (MWSCAS).

[20]  A. Gamal,et al.  Miniaturized integration of a fluorescence microscope , 2011, Nature Methods.

[21]  Jun Ohta,et al.  An implantable CMOS device for blood-flow imaging during experiments on freely moving rats , 2014 .

[22]  Jun Ohta,et al.  An implantable image sensor with self-reset function for brain imaging , 2014, 2014 IEEE Biomedical Circuits and Systems Conference (BioCAS) Proceedings.