Stress analysis in a pedicle screw fixation system with flexible rods in the lumbar spine

Abstract Breakage of screws has been one of the most common complications in spinal fixation systems. However, no studies have examined the breakage risk of pedicle screw fixation systems that use flexible rods, even though flexible rods are currently being used for dynamic stabilization. In this study, the risk of breakage of screws for the rods with various flexibilities in pedicle screw fixation systems is investigated by calculating the von Mises stress as a breakage risk factor using finite element analysis. Three-dimensional finite element models of the lumbar spine with posterior one-level spinal fixations at L4—L5 using four types of rod (a straight rod, a 4 mm spring rod, a 3 mm spring rod, and a 2 mm spring rod) were developed. The von Mises stresses in both the pedicle screws and the rods were analysed under flexion, extension, lateral bending, and torsion moments of 10 N m with a follower load of 400 N. The maximum von Mises stress, which was concentrated on the neck region of the pedicle screw, decreased as the flexibility of the rod increased. However, the ratio of the maximum stress in the rod to the yield stress increased substantially when a highly flexible rod was used. Thus, the level of rod flexibility should be considered carefully when using flexible rods for dynamic stabilization because the intersegmental motion facilitated by the flexible rod results in rod breakage.

[1]  oji,et al.  Effects of lumbar spinal fusion on the other lumbar intervertebral levels (three-dimensional finite element analysis) , .

[2]  V K Goel,et al.  Cancellous bone Young's modulus variation within the vertebral body of a ligamentous lumbar spine--application of bone adaptive remodeling concepts. , 1995, Journal of biomechanical engineering.

[3]  Stephen J. Ferguson,et al.  Factors influencing stresses in the lumbar spine after the insertion of intervertebral cages: finite element analysis , 2003, European Spine Journal.

[4]  G. Sapkas,et al.  Complications and Problems Related to Pedicle Screw Fixation of the Spine , 2003, Clinical orthopaedics and related research.

[5]  F. Netter Atlas of Human Anatomy , 1967 .

[6]  A. Rohlmann,et al.  Influence of graded facetectomy and laminectomy on spinal biomechanics , 2003, European Spine Journal.

[7]  D R Benson,et al.  Early failure of short-segment pedicle instrumentation for thoracolumbar fractures. A preliminary report. , 1993, The Journal of bone and joint surgery. American volume.

[8]  Antonius Rohlmann,et al.  Analysis of the influence of disc degeneration on the mechanical behaviour of a lumbar motion segment using the finite element method. , 2006, Journal of biomechanics.

[9]  K. L. Moore,et al.  Clinically Oriented Anatomy , 1985 .

[10]  M M Panjabi,et al.  Three-Dimensional Movements of the Whole Lumbar Spine and Lumbosacral Joint , 1989, Spine.

[11]  S E Heim,et al.  Transpedicle instrumentation in the degenerative spine. , 1997, Clinical orthopaedics and related research.

[12]  P. McAfee,et al.  Survivorship Analysis of Pedicle Spinal Instrumentation , 1991, Spine.

[13]  G. Bergmann,et al.  Estimation of muscle forces in the lumbar spine during upper-body inclination. , 2001, Clinical biomechanics.

[14]  H. Tullos,et al.  Reduction of Severe Spondylolisthesis in Children , 1969, Southern medical journal.

[15]  Kyung-Woo Park,et al.  Nitinol spring rod dynamic stabilization system and Nitinol memory loops in surgical treatment for lumbar disc disorders: short-term follow up. , 2007, Neurosurgical focus.

[16]  S. Yerby,et al.  Loading of pedicle screws within the vertebra. , 1997, Journal of biomechanics.

[17]  R-M Lin,et al.  Biomechanical investigation of pedicle screw-vertebrae complex: a finite element approach using bonded and contact interface conditions. , 2003, Medical engineering & physics.

[18]  R. Castelein,et al.  Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations , 2002, European Spine Journal.

[19]  B. Cunningham,et al.  Static and Cyclical Biomechanical Analysis of Pedicle Screw Spinal Constructs , 1993, Spine.

[20]  O. Böstman,et al.  Complications of transpedicular lumbosacral fixation for non-traumatic disorders. , 1997, The Journal of bone and joint surgery. British volume.

[21]  Sung Kyu Ha,et al.  Finite element modeling of multi-level cervical spinal segments (C3-C6) and biomechanical analysis of an elastomer-type prosthetic disc. , 2006, Medical engineering & physics.

[22]  S. Esses,et al.  Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. , 1993, Spine.

[23]  R. Chesnut,et al.  Early failure of short-segment pedicle instrumentation for thoracolumbar fractures. A preliminary report. , 1994, The Journal of bone and joint surgery. American volume.

[24]  D. E. Swartz,et al.  A Biomechanical Study of the Fatigue Characteristics of Thoracolumbar Fixation Implants in a Calf Spine Model , 1992, Spine.

[25]  S. Chueh,et al.  Failure analysis of broken pedicle screws on spinal instrumentation. , 2005, Medical engineering & physics.

[26]  R. Roy-Camille,et al.  [Osteosynthesis of dorsal, lumbar, and lumbosacral spine with metallic plates screwed into vertebral pedicles and articular apophyses]. , 1970, La Presse medicale.

[27]  Zheng-Cheng Zhong,et al.  Finite element analysis of the lumbar spine with a new cage using a topology optimization method. , 2006, Medical engineering & physics.