Application of STATCOM to improve the high-voltage-ride-through capability of wind turbine generator

Variable speed wind turbine with full scale converter or so-called type-D wind turbine generator worldwide installation has been significantly increased in the last few years. Voltage Swell in the grid side may cause the wind turbine to be disconnected from the grid. In this paper, STATCOM is applied to improve the high voltage ride through capability of type-D wind turbine during voltage swell in the grid side. Simulation is carried out using MATLAB/Simulink software. Results show that STATCOM can significantly improve the high voltage ride through (HVRT) capability of type-D wind turbine and prevents it from being disconnected from the grid during certain level of voltage swell in the grid side.

[1]  Chen Jian,et al.  Simplified Active and Reactive Power Control of Doubly Fed Induction Generator and the Simulation with STATCOM , 2009, 2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition.

[2]  Bhim Singh,et al.  Three-Level 12-Pulse STATCOM with Constant DC Link Voltage , 2009, 2009 Annual IEEE India Conference.

[3]  R. Blasco-Gimenez,et al.  STATCOM-controlled HVDC Power Transmission for Large Offshore Wind Farms: Engineering Issues , 2006, IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics.

[4]  V. Mahajan Power System Stability Improvement with Flexible A.C. Transmission System (FACTs) Controller , 2008, 2008 Joint International Conference on Power System Technology and IEEE Power India Conference.

[5]  R.G. Harley,et al.  Real-Time Implementation of a STATCOM on a Wind Farm Equipped With Doubly Fed Induction Generators , 2006, IEEE Transactions on Industry Applications.

[6]  G. Sybille,et al.  Modeling and simulation of a distribution STATCOM using Simulink's Power System Blockset , 2001, IECON'01. 27th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.37243).

[7]  M. Baran,et al.  STATCOM Impact Study on the Integration of a Large Wind Farm into a Weak Loop Power System , 2008, 2006 IEEE PES Power Systems Conference and Exposition.

[8]  R. Teodorescu,et al.  Overview of recent grid codes for wind power integration , 2010, 2010 12th International Conference on Optimization of Electrical and Electronic Equipment.

[9]  Sathyajith Mathew,et al.  Wind energy and environment , 2006 .

[10]  J. J. Paserba How FACTS controllers benefit AC transmission systems , 2003, 2003 IEEE PES Transmission and Distribution Conference and Exposition (IEEE Cat. No.03CH37495).

[11]  Sathyajith Mathew,et al.  Wind energy conversion systems , 2006 .