Feasibility of heat recovery for district heating based on Cloud Computing Industrial Park

Heat recovery has been an effective way to improve the energy efficiency of industrial park. Most studies have focused on a single source of waste heat to be reused for energy system of industries. Generally, the lower temperature waste heat is suitable to be the heat source of heat pump for district heating. With the development of information technology, it is possible to find the energy-intensive data centers allocated together to be cooled with the same cooling system, which is called Cloud Computing Industrial Park. As for the data centers based on CCHP system, the waste heat source could be both the cooling water of power plant and the chilled water from the cooling system of data centers. In the present study of cloud computing industrial park in China, two possible heat recovery schemes were proposed and optimized. Consequently, the waste heat from data centers will be the first option of the heat source of district heating. While cooling water carrying waste heat from low-pressure turbine will be supplementary to the first option for providing enough heat for district heating in order to avoid the risk of the shortage of heating. In this case, site-wide analysis by proposing a optimized operation mode enable the operators to control a complete site while considering the energy demands and heat recovery opportunities from each process unit.

[1]  Zheng Xuejing,et al.  A survey of district heating systems in the heating regions of northern China , 2014 .

[2]  Ian C. Kemp,et al.  Pinch Analysis and Process Integration: A User Guide on Process Integration for the Efficient Use of Energy , 2007 .

[3]  Jaume Salom,et al.  The location as an energy efficiency and renewable energy supply measure for data centres in Europe , 2015 .

[4]  H. Ravn,et al.  The role of district heating in the future Danish energy system , 2012 .

[5]  Bernd Möller,et al.  Heat Roadmap Europe: Combining district heating with heat savings to decarbonise the EU energy system , 2014 .

[6]  Gerard F. Jones,et al.  A review of data center cooling technology, operating conditions and the corresponding low-grade waste heat recovery opportunities , 2014 .

[7]  Yi Jiang,et al.  Key issues and solutions in a district heating system using low-grade industrial waste heat , 2015 .

[8]  Sven Werner,et al.  District heating in sequential energy supply , 2012 .

[9]  Brian Vad Mathiesen,et al.  Limiting biomass consumption for heating in 100% renewable energy systems , 2012 .

[10]  Brian Vad Mathiesen,et al.  The role of district heating in future renewable energy systems , 2010 .

[11]  Matthias Wissner,et al.  Regulation of district-heating systems , 2014 .

[12]  Boqiang Lin,et al.  Electricity saving potential of the power generation industry in China , 2012 .

[13]  Michael G. Pollitt,et al.  An assessment of the present and future opportunities for combined heat and power with district heating (CHP-DH) in the United Kingdom , 2010 .

[14]  Brian Vad Mathiesen,et al.  4th Generation District Heating (4GDH) Integrating smart thermal grids into future sustainable energy systems , 2014 .

[15]  Thomas Nuytten,et al.  Flexibility of a combined heat and power system with thermal energy storage for district heating , 2013 .

[16]  Xia Chen,et al.  Energy saving and emission reduction of China's urban district heating , 2013 .

[17]  Henrik Lund,et al.  A renewable energy system in Frederikshavn using low-temperature geothermal energy for district heating , 2011 .

[18]  Marco Filippo Torchio Comparison of district heating CHP and distributed generation CHP with energy, environmental and economic criteria for Northern Italy , 2015 .