Quantitative Analysis of Calcium Spikes in Noisy Fluorescent Background

Intracellular calcium signals are studied by laser-scanning confocal fluorescence microscopy. The required spatio-temporal resolution makes description of calcium signals difficult because of the low signal-to-noise ratio. We designed a new procedure of calcium spike analysis based on their fitting with a model. The accuracy and precision of calcium spike description were tested on synthetic datasets generated either with randomly varied spike parameters and Gaussian noise of constant amplitude, or with constant spike parameters and Gaussian noise of various amplitudes. Statistical analysis was used to evaluate the performance of spike fitting algorithms. The procedure was optimized for reliable estimation of calcium spike parameters and for dismissal of false events. A new algorithm was introduced that corrects the acquisition time of pixels in line-scan images that is in error due to sequential acquisition of individual pixels along the space coordinate. New software was developed in Matlab and provided for general use. It allows interactive dissection of temporal profiles of calcium spikes from x-t images, their fitting with predefined function(s) and acceptance of results on statistical grounds, thus allowing efficient analysis and reliable description of calcium signaling in cardiac myocytes down to the in situ function of ryanodine receptors.

[1]  Heping Cheng,et al.  Calcium signaling between sarcolemmal calcium channels and ryanodine receptors in heart cells. , 2002, Frontiers in bioscience : a journal and virtual library.

[2]  E. Lakatta,et al.  Amplitude distribution of calcium sparks in confocal images: theory and studies with an automatic detection method. , 1999, Biophysical journal.

[3]  Takuji Nishimura,et al.  Mersenne twister: a 623-dimensionally equidistributed uniform pseudo-random number generator , 1998, TOMC.

[4]  Christopher W. Ward,et al.  Time Course of Individual Ca2+ Sparks in Frog Skeletal Muscle Recorded at High Time Resolution , 1999, The Journal of general physiology.

[5]  Donald M Bers,et al.  Voltage Dependence of Cardiac Excitation–Contraction Coupling: Unitary Ca2+ Current Amplitude and Open Channel Probability , 2007, Circulation research.

[6]  L. Csernoch,et al.  Improved spark and ember detection using stationary wavelet transforms. , 2010, Journal of theoretical biology.

[7]  E. Lakatta,et al.  &bgr;-Adrenergic Stimulation Synchronizes Intracellular Ca2+ Release During Excitation-Contraction Coupling in Cardiac Myocytes , 2001, Circulation research.

[8]  W. Lederer,et al.  Calcium sparks: elementary events underlying excitation-contraction coupling in heart muscle. , 1993, Science.

[9]  E. Lakatta,et al.  Thermodynamically irreversible gating of ryanodine receptors in situ revealed by stereotyped duration of release in Ca(2+) sparks. , 2002, Biophysical journal.

[10]  Ca2+ release flux underlying Ca2+ transients and Ca2+ sparks in skeletal muscle. , 2002 .

[11]  Mark-Anthony Bray,et al.  Multidimensional detection and analysis of Ca2+ sparks in cardiac myocytes. , 2007, Biophysical journal.

[12]  E. Lakatta,et al.  Termination of Ca2+ release by a local inactivation of ryanodine receptors in cardiac myocytes. , 1998, Proceedings of the National Academy of Sciences of the United States of America.

[13]  A. Zahradníková,et al.  Local calcium release activation by DHPR calcium channel openings in rat cardiac myocytes , 2008, The Journal of physiology.

[14]  A. Zahradníková,et al.  Construction of Calcium Release Sites in Cardiac Myocytes , 2012, Front. Physio..

[15]  Challenging quantal calcium signaling in cardiac myocytes , 2010, The Journal of general physiology.

[16]  W. Lederer,et al.  Calcium sparks and [Ca2+]i waves in cardiac myocytes. , 1996, The American journal of physiology.

[17]  A. Zahradníková,et al.  Calcium spike variability in cardiac myocytes results from activation of small cohorts of ryanodine receptor 2 channels , 2012, The Journal of physiology.

[18]  W. Lederer,et al.  Spatial non-uniformities in [Ca2+]i during excitation-contraction coupling in cardiac myocytes. , 1994, Biophysical journal.

[19]  E. Lakatta,et al.  Direct measurement of SR release flux by tracking ‘Ca2+ spikes’ in rat cardiac myocytes , 1998, The Journal of physiology.

[20]  Christian Soeller,et al.  Analysis of ryanodine receptor clusters in rat and human cardiac myocytes , 2007, Proceedings of the National Academy of Sciences.

[21]  Ivan Zahradník,et al.  Kinetics of calcium spikes in rat cardiac myocytes , 2007, The Journal of physiology.

[22]  Christian Soeller,et al.  Increasing sensitivity of Ca2+ spark detection in noisy images by application of a matched-filter object detection algorithm. , 2008, Biophysical journal.