Blood Coagulation Testing Smartphone Platform Using Quartz Crystal Microbalance Dissipation Method

Blood coagulation function monitoring is important for people who are receiving anticoagulation treatment and a portable device is needed by these patients for blood coagulation self-testing. In this paper, a novel smartphone based blood coagulation test platform was proposed. It was developed based on parylene-C coated quartz crystal microbalance (QCM) dissipation measuring and analysis. The parylene-C coating constructed a robust and adhesive surface for fibrin capturing. The dissipation factor was obtained by measuring the frequency response of the sensor. All measured data were sent to a smartphone via Bluetooth for dissipation calculation and blood coagulation results computation. Two major coagulation indexes, activated partial thromboplastin time (APTT) and prothrombin time (PT) were measured on this platform compared with results by a commercial hemostasis system in a clinical laboratory. The measurement results showed that the adjusted R-square (R2) value for APTT and PT measurements were 0.985 and 0.961 respectively. The QCM dissipation method for blood coagulation measurement was reliable and effective and the platform together with the QCM dissipation method was a promising solution for point of care blood coagulation testing.

[1]  L. Alberio,et al.  Monitoring thrombin generation by electrochemistry: development of an amperometric biosensor screening test for plasma and whole blood. , 2009, Clinical chemistry.

[2]  Janos Vörös,et al.  Comparison of FBAR and QCM-D sensitivity dependence on adlayer thickness and viscosity , 2011 .

[3]  Hans P. Wendel,et al.  Bioapplications of acoustic crystals, a review , 2018 .

[4]  Mohieddine Benammar,et al.  Quartz Crystal Microbalance Electronic Interfacing Systems: A Review , 2017, Sensors.

[5]  U. Ziemann,et al.  Point-of-care testing for emergency assessment of coagulation in patients treated with direct oral anticoagulants , 2017, Critical Care.

[6]  E. Sackmann,et al.  Comparison of the QCM and the SPR method for surface studies and immunological applications , 1995 .

[7]  J. Dinardo,et al.  TEG and ROTEM: Technology and clinical applications , 2014, American journal of hematology.

[8]  Peter Lieberzeit,et al.  QCM-based rapid detection of PCR amplification products of Ehrlichia canis. , 2018, Analytica chimica acta.

[9]  Giorgio Pennazza,et al.  Electronic Interface for a Gas Sensor System Based on 32 MHz QCMs: Design and Calibration , 2018, IEEE Sensors Journal.

[10]  Chunyan Yao,et al.  Detection of Fibrinogen and Coagulation Factor VIII in Plasma by a Quartz Crystal Microbalance Biosensor , 2013, Sensors.

[11]  Shing‐Jong Lin,et al.  Quantitative evaluation of thrombosis by electrochemical methodology. , 2003, Thrombosis research.

[12]  F. Pompei,et al.  Effects of temperature on bleeding time and clotting time in normal male and female volunteers. , 1995, Critical care medicine.

[13]  A. Killard,et al.  Modelling of blood component flexibility using quartz crystal microbalance , 2014 .

[14]  E. Thormann,et al.  Quartz Crystal Microbalance with Dissipation (QCM-D) studies of the viscoelastic response from a continuously growing grafted polyelectrolyte layer. , 2013, Journal of colloid and interface science.

[15]  C. Hofer,et al.  Coagulation Monitoring: Current Techniques and Clinical Use of Viscoelastic Point-of-Care Coagulation Devices , 2008, Anesthesia and analgesia.

[16]  Bengt Herbert Kasemo,et al.  Frequency and dissipation-factor responses to localized liquid deposits on a QCM electrode , 1996 .

[17]  I Lundström,et al.  Surface plasmon resonance (SPR) analysis of coagulation in whole blood with application in prothrombin time assay. , 1999, Biosensors & bioelectronics.

[18]  A. Ray,et al.  Studies of Adsorption and Viscoelastic Properties of Proteins onto Liquid Crystal Phthalocyanine Surface Using Quartz Crystal Microbalance with Dissipation Technique , 2008 .

[19]  Wen Wang,et al.  Airborne particulate matter classification and concentration detection based on 3D printed virtual impactor and quartz crystal microbalance sensor , 2016, 2016 IEEE 29th International Conference on Micro Electro Mechanical Systems (MEMS).

[20]  G. Sauerbrey Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur Mikrowägung , 1959 .

[21]  A. Imbriano [Blood coagulation]. , 1955, La Semana medica.

[22]  G. Sauerbrey,et al.  Use of quartz vibration for weighing thin films on a microbalance , 1959 .

[23]  L. Alberio,et al.  Rivaroxaban: Quantification by anti-FXa assay and influence on coagulation tests: a study in 9 Swiss laboratories. , 2012, Thrombosis research.

[24]  J. Weitz,et al.  Coagulation assays. , 2005, Circulation.

[25]  M. Maitz,et al.  Blood coagulation on biomaterials requires the combination of distinct activation processes. , 2009, Biomaterials.

[26]  Wei Zhang,et al.  Stability enhanced, repeatability improved Parylene-C passivated on QCM sensor for aPTT measurement. , 2017, Biosensors & bioelectronics.

[27]  Sean X. Liu,et al.  Application of Kevin—Voigt Model in Quantifying Whey Protein Adsorption on Polyethersulfone Using QCM-D , 2009 .

[28]  Ashwin A. Seshia,et al.  Multifrequency acoustics as a probe of mesoscopic blood coagulation dynamics , 2016 .

[29]  L. Schlapbach,et al.  Study of adsorption and viscoelastic properties of proteins with a quartz crystal microbalance by measuring the oscillation amplitude. , 2003, Journal of colloid and interface science.

[30]  Munawar Hussain,et al.  QCM-D providing new horizon in the domain of sensitivity range and information for haemostasis of human plasma. , 2015, Biosensors & bioelectronics.

[31]  Pablo García,et al.  Design and Validation of a 150 MHz HFFQCM Sensor for Bio-Sensing Applications , 2017, Sensors.

[32]  Bo Nilsson,et al.  Quartz crystal microbalance-with dissipation monitoring (QCM-D) for real time measurements of blood coagulation density and immune complement activation on artificial surfaces. , 2005, Biosensors & bioelectronics.

[33]  Munawar Hussain,et al.  QCM-D surpassing clinical standard for the dose administration of new oral anticoagulant in the patient of coagulation disorders. , 2018, Biosensors & bioelectronics.

[34]  江口 和夫,et al.  肝・胆道疾患の Thrombelastography , 1977 .

[35]  B. Kasemo,et al.  QCM Operation in Liquids:  An Explanation of Measured Variations in Frequency and Q Factor with Liquid Conductivity. , 1996, Analytical chemistry.

[36]  B. Kasemo,et al.  Simultaneous frequency and dissipation factor QCM measurements of biomolecular adsorption and cell adhesion. , 1997, Faraday discussions.

[37]  Hakan Urey,et al.  A cartridge based sensor array platform for multiple coagulation measurements from plasma. , 2015, Lab on a chip.

[38]  M. Hegner,et al.  Microrheological Coagulation Assay Exploiting Micromechanical Resonators. , 2017, Analytical chemistry.

[39]  Kenichi A. Tanaka,et al.  Point-of-Care Coagulation Testing in Cardiac Surgery , 2017, Seminars in Thrombosis and Hemostasis.

[40]  Serife Seyda Pirinçci,et al.  Label-Free QCM Immunosensor for the Detection of Ochratoxin A , 2017, Sensors.

[41]  Qiuquan Guo,et al.  Micro-electromechanical film bulk acoustic sensor for plasma and whole blood coagulation monitoring. , 2017, Biosensors & bioelectronics.

[42]  Christiane Ziegler,et al.  Investigation of prothrombin time in human whole-blood samples with a quartz crystal biosensor. , 2010, Analytical chemistry.

[43]  T. Cheng,et al.  A piezoelectric quartz crystal sensor for the determination of coagulation time in plasma and whole blood. , 1998, Biosensors & bioelectronics.

[44]  M. Ranucci,et al.  Point-of-Care Coagulation Tests Monitoring of Direct Oral Anticoagulants and Their Reversal Therapy: State of the Art , 2017, Seminars in Thrombosis and Hemostasis.

[45]  S. Mallett Clinical Utility of Viscoelastic Tests of Coagulation (TEG/ROTEM) in Patients with Liver Disease and during Liver Transplantation , 2015, Seminars in Thrombosis & Hemostasis.

[46]  Yong Wang,et al.  A Miniature System for Separation and Detection of PM Based on 3-D Printed Virtual Impactor and QCM Sensor , 2018, IEEE Sensors Journal.