Impedance plethysmography in the diagnosis of asymptomatic deep vein thrombosis in hip surgery. A venography-controlled study.

We prospectively evaluated the accuracy of computerized impedance plethysmography (CIP) in the diagnosis of asymptomatic deep vein thrombosis (DVT) in 246 consecutive high-risk patients scheduled for hip surgery, with bilateral venography used for comparison. The CIP was performed as a surveillance program every third day. If the CIP remained negative, bilateral venography was performed on postoperative day 10 +/- 1 or on day of treatment 14 +/- 1 in nonoperated-on patients. If the CIP became positive, venography was performed within 24 hours. The sensitivity and specificity of CIP for proximal and distal DVT were 19% (confidence interval [CI], 13% to 24%) and 91% (CI, 87% to 94%), respectively. The positive and negative predictive values were 52% (CI, 38% to 65%) and 70% (CI, 65% to 74%), respectively. The sensitivity and specificity of CIP for proximal DVT were 24% (CI, 13% to 34%) and 90% (CI, 87% to 94%), respectively; the positive and negative predictive values were 31% (CI, 20% to 51%) and 87% (CI, 83% to 90%), respectively. We conclude that, because of its low sensitivity, CIP cannot be used in the surveillance of DVT in high-risk patients or for outcome measurements in clinical trials on DVT prophylaxis.

[1]  G. Agnelli,et al.  Diagnostic Accuracy of Computerized Impedance Plethysmography in the Diagnosis of Symptomatic Deep Vein Thrombosis: A Controlled Venographic Study , 1990, Angiology.

[2]  J. Hirsh,et al.  An Evaluation of Impedance Plethysmography and 125I-Fibrinogen Leg Scanning in Patients following Hip Surgery , 1989, Thrombosis and Haemostasis.

[3]  J. McGahan,et al.  Diagnosis of deep-vein thrombosis using duplex ultrasound. , 1989, Annals of internal medicine.

[4]  L. Borris,et al.  Comparison of Real-Time B-Mode Ultrasonog raphy and Bilateral Ascending Phlebography for Detection of Postoperative Deep Vein Thrombosis Following Elective Hip Surgery , 1989, Thrombosis and Haemostasis.

[5]  H. Büller,et al.  Detection of deep-vein thrombosis by real-time B-mode ultrasonography. , 1989, The New England journal of medicine.

[6]  R. Collins,et al.  Reduction in Fatal Pulmonary Embolism and Venous Thrombosis by Perioperative Administration of Subcutaneous Heparin , 1989 .

[7]  J. Cronan,et al.  Compression ultrasonography for the detection of deep venous thrombosis in patients who have a fracture of the hip. A prospective study. , 1989, The Journal of bone and joint surgery. American volume.

[8]  R. Collins,et al.  Reduction in fatal pulmonary embolism and venous thrombosis by perioperative administration of subcutaneous heparin. Overview of results of randomized trials in general, orthopedic, and urologic surgery. , 1988, The New England journal of medicine.

[9]  W. Harris,et al.  Surveillance of deep vein thrombosis in asymptomatic total hip replacement patients. Impedance phlebography and fibrinogen scanning versus roentgenographic phlebography. , 1988, American journal of surgery.

[10]  I. Vujic,et al.  The comparative value of noninvasive testing for diagnosis and surveillance of deep vein thrombosis. , 1988, Journal of vascular surgery.

[11]  M. Bettmann,et al.  Contrast venography of the leg: diagnostic efficacy, tolerance, and complication rates with ionic and nonionic contrast media. , 1987, Radiology.

[12]  P. Prandoni,et al.  COMPUTERIZED IMPEDANCE PLETHYSMOGRAPHY, A NEW PLETHYSMOGRAPHIC METHOD TO DETECT DEEP VEIN THROMBOSIS , 1987 .

[13]  H. Büller,et al.  Serial impedance plethysmography for suspected deep venous thrombosis in outpatients. The Amsterdam General Practitioner Study. , 1986, The New England journal of medicine.

[14]  Denise H. Kinch,et al.  Diagnostic efficacy of impedance plethysmography for clinically suspected deep-vein thrombosis. A randomized trial. , 2020, Annals of internal medicine.

[15]  D. Sackett,et al.  The Ends of Human Life: Medical Ethics in a Liberal Polity , 1992, Annals of Internal Medicine.

[16]  E. Länsimies,et al.  The 125I-labelled fibrinogen uptake test in elective hip surgery. , 1985, Annals of clinical research.

[17]  D. Sackett,et al.  The value of adding impedance plethysmography to 125I-fibrinogen leg scanning for the detection of deep vein thrombosis in high risk surgical patients: a comparative study between patients undergoing general surgery and hip surgery. , 1979, Thrombosis research.

[18]  G. McGarrity,et al.  The fibrinogen uptake test after hip surgery , 1978, The British journal of surgery.

[19]  N. Browse Diagnosis of deep-vein thrombosis. , 1978, British medical bulletin.

[20]  P. Arnow,et al.  Aspirin, hyperventilation, and cerebellar infarction in sickle cell disease. , 1978, Archives of internal medicine.

[21]  W. Harris,et al.  Cuff-impedance phlebography and 125I fibrinogen scanning versus roentgenographic phlebography for diagnosis of thrombophlebitis following hip surgery. A preliminary report. , 1976, The Journal of bone and joint surgery. American volume.

[22]  J. Cranley,et al.  The diagnosis of deep venous thrombosis. Fallibility of clinical symptoms and signs. , 1976, Archives of surgery.

[23]  S. Baum,et al.  Comparison of 125I fibrinogen count scanning with phlebography for detection of venous thrombi after elective hip surgery. , 1975, The New England journal of medicine.

[24]  K. Rabinov,et al.  Roentgen diagnosis of venous thrombosis in the leg. , 1972, Archives of surgery.

[25]  K. Haeger,et al.  Problems of Acute Deep Venous Thrombosis , 1969, Angiology.