Patient specific biomodel of the whole aorta - the importance of calcified plaque removal.

BACKGROUND The use of anatomical models produced by 3D printing technique (rapid prototyping, RP) is gaining increased acceptance as a complementary tool for planning complex surgical interventions. This paper describes a method for creating a patient specific replica of the whole aorta. METHODS Computed tomography angiography (CTA) DICOM-data was converted to a three-dimensional computer aided design-model (CAD) of the inner wall of the aorta representing the lumen where the calcified plaque contribution was removed in a multi-step editing-manoeuvre. The edited CAD-model was used for creating a physical plaster model of the true lumen in a 3D-printer. Elastic and transparent silicon was applied onto the plaster model, which was then removed leaving a silicon replica of the aorta. RESULTS The median (interquartile range) difference between diameters obtained from CTA- and RP plaster-model at 19 predefined locations was 0.5 mm (1 mm) which corresponds to a relative median difference of 4.6% (7.0%). The average wall thickness of the silicone model was 3.5 mm. The elasticity property and performance during intervention was good with an acceptable transparency. CONCLUSIONS The integration of RP-techniques with CAD based reconstruction of 3D-medical imaging data provides the needed tools for making a truly patient specific replica of the whole aorta with high accuracy. Plaque removal postprocessing is necessary to obtain a true inner wall configuration.

[1]  R J Winder,et al.  Abdominal aortic aneurysm and stent graft phantom manufactured by medical rapid prototyping , 2002, Journal of medical engineering & technology.

[2]  L. Boussel,et al.  In vitro non-rigid life-size model of aortic arch aneurysm for endovascular prosthesis assessment. , 2008, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[3]  Y. Toshev,et al.  MEDICAL RAPID PROTOTYPING APPLICATIONS AND METHODS , 2005 .

[4]  F. Migliavacca,et al.  Use of rapid prototyping models in the planning of percutaneous pulmonary valved stent implantation , 2007, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[5]  P Lermusiaux,et al.  Aortic Aneurysm: Construction of a Life-size Model by Rapid Prototyping , 2001, Annals of vascular surgery.

[6]  W. Hopfenmüller,et al.  Dual energy CT of peripheral arteries: effect of automatic bone and plaque removal on image quality and grading of stenoses. , 2008, European journal of radiology.

[7]  Christoph Thomas,et al.  Automatic lumen segmentation in calcified plaques: dual-energy CT versus standard reconstructions in comparison with digital subtraction angiography. , 2010, AJR. American journal of roentgenology.

[8]  W A Kalender,et al.  Rapid protyping technology in medicine--basics and applications. , 1999, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[9]  Maciej Orkisz,et al.  Computer-assisted analysis of three-dimensional MR angiograms. , 2002, Radiographics : a review publication of the Radiological Society of North America, Inc.

[10]  Miroslav Trajanović,et al.  Medical applications of rapid prototyping , 2007 .

[11]  Terry Wohlers,et al.  Future potential of rapid prototyping and manufacturing around the world , 1995 .

[12]  Chee Kai Chua,et al.  Rapid Prototyping:Principles and Applications , 2010 .

[13]  K. Lovblad,et al.  From patient to model: stereolithographic modeling of the cerebral vasculature based on rotational angiography. , 2005, AJNR. American journal of neuroradiology.

[14]  Madhavan L Raghavan,et al.  Regional distribution of wall thickness and failure properties of human abdominal aortic aneurysm. , 2006, Journal of biomechanics.

[15]  C. Kerber,et al.  Rapid prototyping to create vascular replicas from CT scan data: Making tools to teach, rehearse, and choose treatment strategies , 2005, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[16]  D M Erickson,et al.  An opinion survey of reported benefits from the use of stereolithographic models. , 1999, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[17]  Jürgen Hennig,et al.  Rapid vessel prototyping: vascular modeling using 3t magnetic resonance angiography and rapid prototyping technology , 2005, Magnetic Resonance Materials in Physics, Biology and Medicine.

[18]  P. Dobrin,et al.  Animal Models of Aneurysms , 1999, Annals of vascular surgery.

[19]  B. Tomancok,et al.  Cerebrovascular stereolithographic biomodeling for aneurysm surgery. Technical note. , 2004, Journal of neurosurgery.

[20]  T. V. How,et al.  Development of a Simulator for Endovascular Repair of Abdominal Aortic Aneurysms , 1998, Annals of Biomedical Engineering.

[21]  A. Magnusson,et al.  Pelvicaliceal biomodeling as an aid to achieving optimal access in percutaneous nephrolithotripsy. , 2006, Journal of endourology.