A 7T spine array based on electric dipole transmitters

The goal of this study was to explore the feasibility of using an array of electric dipole antennas for RF transmission in spine MRI at high fields.

[1]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[2]  A. Webb,et al.  A radiofrequency coil configuration for imaging the human vertebral column at 7 T. , 2011, Journal of magnetic resonance.

[3]  J A de Zwart,et al.  Fast lipid‐suppressed MR temperature mapping with echo‐shifted gradient‐echo imaging and spectral‐spatial excitation , 1999, Magnetic resonance in medicine.

[4]  D. Sodickson,et al.  Optimizing 7 T Spine Array Design through Offsetting of Transmit and Receive Elements and Quadrature Excitation , 2009 .

[5]  Klaas P. Pruessmann,et al.  Travelling-wave nuclear magnetic resonance , 2009, Nature.

[6]  Peter R. Luijten,et al.  Optimization of the radiative antenna for 7‐T magnetic resonance body imaging , 2013 .

[7]  S. Silver Microwave antenna theory and design , 1949 .

[8]  Peter R Luijten,et al.  The fractionated dipole antenna: A new antenna for body imaging at 7 Tesla , 2016, Magnetic resonance in medicine.

[9]  C A T van den Berg,et al.  Design of a radiative surface coil array element at 7 T: The single‐side adapted dipole antenna , 2011, Magnetic resonance in medicine.

[10]  D. Sodickson,et al.  Whole body traveling wave magnetic resonance imaging at high field strength: Homogeneity, efficiency, and energy deposition as compared with traditional excitation mechanisms , 2012, Magnetic resonance in medicine.

[11]  Bing Wu,et al.  7T Human Spine Imaging Arrays With Adjustable Inductive Decoupling , 2010, IEEE Transactions on Biomedical Engineering.

[12]  Jeff Duyn,et al.  Improved Bloch‐Siegert based B1 mapping by reducing off‐resonance shift , 2013, NMR in biomedicine.

[13]  J. Helpern,et al.  High‐resolution human cervical spinal cord imaging at 7 T , 2012, NMR in biomedicine.

[14]  M. Ladd,et al.  An Eight-Channel Phased Array RF Coil for Spine MR Imaging at 7 T , 2009, Investigative radiology.

[15]  Derek Seeber,et al.  Floating shield current suppression trap , 2004 .

[16]  C A T van den Berg,et al.  Characterization of transceive surface element designs for 7 tesla magnetic resonance imaging of the prostate: radiative antenna and microstrip , 2012, Physics in medicine and biology.

[17]  Daniel K Sodickson,et al.  Characterization of a dielectric phantom for high-field magnetic resonance imaging applications. , 2014, Medical physics.

[18]  Daniel Sodickson,et al.  4572 A 7 T 8 channel transmit-receive dipole array for head imaging : dipole element and coil evaluation , 2013 .

[19]  Julien Cohen-Adad,et al.  Nineteen‐channel receive array and four‐channel transmit array coil for cervical spinal cord imaging at 7T , 2014, Magnetic resonance in medicine.

[20]  Daniel Sodickson,et al.  The Circular Dipole , 2013 .

[21]  K. Kuroda,et al.  A precise and fast temperature mapping using water proton chemical shift , 1995, Magnetic resonance in medicine.

[22]  M. Shapiro,et al.  MR imaging of the spine at 3T. , 2006, Magnetic resonance imaging clinics of North America.

[23]  Emanuele Schiavi,et al.  SAR reduction in 7T C‐spine imaging using a “dark modes” transmit array strategy , 2014, Magnetic resonance in medicine.