Enhanced performance of SVC via using rotor speed deviation signal (RSDS)

Transient stability enhancement through using a Static Var Compensator (SVC) and Rotor Speed Deviation Signal (RSDS) of synchronous machine are thoroughly investigated in this paper. Speed deviation signal of generator as a remote signal is sent to SVC in order to achieve more transient stability. Studies are carried out on Kundur's four machine two-area test system which SVC is implemented on midway of transmission system. The simulation results verify the effectiveness of the proposed method to improve rotor angle stability versus different kinds of disturbances scenarios. The standard benchmark model is used for the analysis in the MATLAB/Simulink environment.

[1]  Youyi Wang,et al.  Transient stability and voltage regulation enhancement via coordinated control of generator excitation and SVC , 2005 .

[2]  A. Salemnia,et al.  Mitigation of subsynchronous oscillations by 48-pulse VSC STATCOM using remote signal , 2009, 2009 IEEE Bucharest PowerTech.

[3]  M. A. Abido,et al.  Simultaneous stabilization of multimachine power systems via genetic algorithms , 1999, IEEE Transactions on Power Systems.

[4]  Rajiv K. Varma,et al.  Damping torque analysis of static VAR system controllers , 1991 .

[5]  Dragan Jovcic,et al.  DC Transmission Grid With Low-Speed Protection Using Mechanical DC Circuit Breakers , 2015, IEEE Transactions on Power Delivery.

[6]  Alexandre Sanfelice Bazanella,et al.  Coordinated design of damping controllers for robustness of power systems stability , 2001 .

[7]  Balarko Chaudhuri,et al.  Wide-area measurement-based stabilizing control of power system considering signal transmission delay , 2004 .

[8]  Sidhartha Panda,et al.  Simultaneous Tuning of Static Var Compensator and Power System Stabilizer Employing Real- Coded Genetic Algorithm , 2008 .

[9]  Alvaro Luna,et al.  Posicast control — A novel approach to mitigate multi-machine power system oscillations in presence of wind farm , 2014, 2014 IEEE PES General Meeting | Conference & Exposition.

[10]  I. Erlich,et al.  Simultaneous coordinated tuning of PSS and FACTS damping controllers in large power systems , 2005, IEEE Transactions on Power Systems.

[11]  Alvaro Luna,et al.  Application of Posicast control method to generator excitation system , 2014, 2014 IEEE 23rd International Symposium on Industrial Electronics (ISIE).

[12]  P. Kundur,et al.  Power system stability and control , 1994 .

[13]  Rajat Majumder,et al.  A unified Smith predictor approach for power system damping control design using remote signals , 2005, IEEE Transactions on Control Systems Technology.

[14]  Xiaoyan Bian,et al.  Coordinated design of probabilistic PSS and SVC damping controllers , 2011 .

[15]  Laszlo Gyugyi,et al.  Understanding FACTS: Concepts and Technology of Flexible AC Transmission Systems , 1999 .

[16]  Wei Yao,et al.  Wide-area damping controller of FACTS devices for inter-area oscillations considering communication time delays , 2014 .

[17]  M. A. Abido,et al.  Coordinated design of a PSS and an SVC-based controller to enhance power system stability , 2003 .

[18]  Amin Safari,et al.  PSS and TCSC damping controller coordinated design using PSO in multi-machine power system , 2010 .

[19]  M. J. Gibbard,et al.  Robust design of fixed-parameter power system stabilisers over a wide range of operating conditions , 1991 .

[20]  B. Chaudhuri,et al.  Wide-area measurement-based stabilizing control of power system considering signal transmission delay , 2004, IEEE Transactions on Power Systems.