Cascaded-systems analyses of photon-counting x-ray detectors

Single-photon counting (SPC) x-ray imaging has the potential to improve image quality and enable new advanced energy-dependent methods. Recently, cascaded systems analysis (CSA) has been extended to the description of the detective quantum efficiency (DQE) of SPC detectors. In this article we apply the new CSA approach to the description of the DQE of hypothetical direct-conversion selenium (Sc) and cadmium zinc telluride (CdZnTc) detectors including the effects of poly-energetic x-ray spectra, stochastic conversion of x-ray energy to electron hole (c-h) pairs, depth-dependent collection of e-h pairs using the Hecht relation, additive electronic noise, and thresholding. Comparisons arc made to an energy-integrating model. For this simple model, with the exception of thick (1- 10 mm) Sc-bascd convertors, we found that the SPC DQE was 5-20 %greater than that of the energy integrating model. This trend was tnw even when additive noise was included in the SPC model and excluded from the energy-integrating model. However, the DQE of SPC detectors with poor collection efficiency (such as thick (<1 mm) Sc detectors) and high levels of additive noise can be degraded by 40-90 % for all energies and x-ray spectra considered. vVhile photon-counting approaches arc not yet ready for routine diagnostic imaging, the available DQE is equal to or higher than that of conventional energy-integrating detectors under a wide range of x-ray energies and convertor thickness. However, like energy-integrating detectors, the DQE of SPC detectors will be degraded by the combination of poor collection efficiency and high levels of additive noise.

[1]  B. Mikulec,et al.  Development of segmented semiconductor arrays for quantum imaging , 2003 .

[2]  Polad M Shikhaliev,et al.  Photon counting multienergy x-ray imaging: effect of the characteristic x rays on detector performance. , 2009, Medical physics.

[3]  Safa Kasap,et al.  X-ray sensitivity of photoconductors: application to stabilized a-Se , 2000 .

[4]  Richard L. Van Metter,et al.  Handbook of Medical Imaging , 2009 .

[5]  Majid Rabbani,et al.  Analysis of signal and noise propagation for several imaging mechanisms , 1989 .

[6]  J A Rowlands,et al.  Optical factors affecting the detective quantum efficiency of radiographic screens. , 1986, Medical physics.

[7]  I. Cunningham,et al.  The detective quantum efficiency of photon-counting x-ray detectors using cascaded-systems analyses. , 2013, Medical physics.

[8]  G. Barnes,et al.  Semiempirical model for generating tungsten target x-ray spectra. , 1991, Medical physics.

[9]  J. Yorkston Recent developments in digital radiography detectors , 2007 .

[10]  I. Miller Probability, Random Variables, and Stochastic Processes , 1966 .

[11]  I A Cunningham,et al.  Fundamental x-ray interaction limits in diagnostic imaging detectors: Frequency-dependent Swank noise. , 2008, Medical physics.

[12]  Jesse Tanguay,et al.  The role of x-ray Swank factor in energy-resolving photon-counting imaging. , 2010, Medical physics.

[13]  Andrew D A Maidment,et al.  A comparative analysis of OTF, NPS, and DQE in energy integrating and photon counting digital x-ray detectors. , 2010, Medical physics.

[14]  G. Knoll Radiation detection and measurement , 1979 .

[15]  R Van Metter,et al.  An application of multivariate moment-generating functions to the analysis of signal and noise propagation in radiographic screen-film systems. , 1990, Medical physics.

[16]  R. K. Swank Measurement of absorption and noise in an x‐ray image intensifier , 1974 .

[17]  Seungman Yun,et al.  Spectral analysis of fundamental signal and noise performances in photoconductors for mammography. , 2012, Medical physics.

[18]  K. Hecht Zum Mechanismus des lichtelektrischen Primärstromes in isolierenden Kristallen , 1932 .

[19]  Athanasios Papoulis,et al.  Probability, Random Variables and Stochastic Processes , 1965 .

[20]  R. K. Swank Absorption and noise in x‐ray phosphors , 1973 .

[21]  Yael Nemirovsky,et al.  Methodology for evaluation of mobility-lifetime product by spectroscopy measurements in CdZnTe spectrometers , 1997 .

[22]  I A Cunningham,et al.  Fundamental x-ray interaction limits in diagnostic imaging detectors: frequency-dependent Swank noise. , 2008, Medical physics.

[23]  Seungman Yun,et al.  Extension of cascaded systems analysis to single-photon-counting x-ray detectors , 2012, Medical Imaging.

[24]  Polad M Shikhaliev,et al.  Projection x-ray imaging with photon energy weighting: experimental evaluation with a prototype detector , 2009, Physics in medicine and biology.

[25]  M. Campbell,et al.  The Medipix3 Prototype, a Pixel Readout Chip Working in Single Photon Counting Mode With Improved Spectrometric Performance , 2006, IEEE Transactions on Nuclear Science.